63
EN
175 mm.
Fig. 4. Bottom view
Rear
rail
Ventilation
valve
Fig. 5. Rear view.
The connection terminals are located at the bottom of the unit,
as shown in the following table:
Item
Terminal
Note
DC switch
On/Off switch
DC input terminal
PV Connector
Battery input
terminal
Battery connector
COM1 port
WiFi connector
COM2 port
CT/RS485 connector
AC Back-up output
terminal
Connection for AC output
AC grid output
terminal
Connection for AC output
Tab. 4. Connection terminals.
4.3. SCREEN INTERFACE AND
WIFI MODULE.
Fig. 6. Synoptic chart view.
Item Indicator
Status
Description
Battery
level
indicator
Off
Battery not connected or communication error.
Always On
Battery in discharge or standby mode,
the indicator shows the battery level.
Single flash
Battery charging, the indicator shows
the battery level.
Power
indicator
Off
Inverter without AC output.
Fast flash
Inverter in self-test status.
Slow flash
Inverter in standby status.
Always On
Inverter in normal status.
Grid
indicator
Off
Disconnected from the grid.
Slow flash
Grid detected but not in grid mode.
Always On
Operating in grid mode.
Alarm
indicator
Off
The inverter operates normally.
Slow flash
The monitoring device is not connected
to the router or base station.
Fast flash
The monitoring device is connected to the router
or base station, but not to the server.
Orange
A warning is detected with the inverter
operating, see the defect on the display.
Red
Alarm or fault detected, see them on the display.
Display
On
Displays inverter operation information.
Off
Display off to save power, press to make
it reappear.
Button
Physical
Switch between display information and
parameter setting with a short or long press.
Fig. 7. Interface functionalities.