5.1. LOCATION.
The inverters of the
EQX2-HT
series have been designed with an
enclosure with IP65 degree of protection, suitable for indoor and
outdoor installations. The following factors should be taken into
account when selecting an installation location for the inverter:
1.
The wall on which the inverters are mounted must be able to
support the weight of the inverter.
2.
The inverter must be installed in a well-ventilated environment.
3.
Make sure that the inverter is not exposed directly to strong
sunlight to avoid operation at excessive temperatures.
The inverter should be installed in a place sheltered from
direct sunlight and rain.
4.
Install the inverter at eye level for easy reading of the data on
the screen and better maintenance.
5.
The ambient temperature of the place where the inverter is
installed must be between -30ºC and +60ºC.
6.
The surface temperature of the inverter can reach up to 75ºC.
To avoid the risk of burns, do not touch the inverter during
operation and install it out of the reach of children.
5.1.1. Installation location.
We recommend installing inverters indoors. However,
if there is no choice but to install outdoors, shows recom-
mended locations, as well as those to avoid:
Fig. 33. Recommended locations for the inverter.
Warning
Do not store flammable and/or explosive materials
near the inverter.
5.1.2. Recommended installation distances.
Installation angle and spacing
: Check that the inverter is in-
stalled on a vertical surface and that it keeps the following min-
imum safety distances with respect to other elements for optimal
ventilation, as shown in :
Fig. 34. Recommended installation distances.
Dimensions
Distance (mm)
A
500
B
300
5.2. ASSEMBLY PROCESS.
Steps:
5.3. ELECTRIC CONNECTION.
Danger
An excessively high voltage on the conductive part of
the inverter may cause electric shock. When installing
the inverter, make sure that the AC and DC sides of the
inverter are completely de-energised.
Warning
Do not connect the positive or negative poles of the
photovoltaic panel to earth, since this may cause major
damage to the inverter.
Warning
Static electricity can damage the inverter's electronic
components. Take the necessary anti-static measures
during installation and maintenance.
Attention
Do not use terminals of different manufacturers or of
different types, other than those included in the acces-
sory pack. SALICRU shall not be held liable for any form
of damage caused by the use of unauthorised terminals.
Attention
Moisture and dust can damage the inverter; check that
the cable gland is tight enough during installation.
The warranty will be void if the inverter is damaged as
a result of an improperly installed cable gland.
5.3.1. General wiring diagram.
This diagram shows the structure and composition of the wiring
of the hybrid inverter from the
EQX2-HT
series, in relation to the
actual project. The installation and wiring must comply with local
Содержание EQUINOX EQX2 4002-HT
Страница 2: ...2 SALICRU...
Страница 53: ...53 ES EQX2 INVERSORES SOLARES DE CONEXI N A RED MANUAL DE USUARIO...
Страница 56: ...56 SALICRU...
Страница 107: ...107 EN EQX2 SOLAR INVERTERS CONNECTED TO THE GRID USER MANUAL...