7
Pre-installation
Installation
PumpWise guidelines
General specification
Trouble shooting
PumpWise and warranty
!
Right Universal Pumps - system operation and
L.E.D. indication
R
ight Universal pumps are designed to protect
customers by responding to unexpected and
unforeseen conditions. Right Universal pumps
will only be switched OFF if the unexpected or
unforeseen conditions are serious.
Right Universal pumps capable of:
• Supply water temperature sensing
• Dry run protection
• Sensing chronic aeration or water starvation
• L.E.D indication of unforeseen system malfunction.
IMPORTANT NOTE
The HOT and COLD pump ends are
identified by RED (hot) and BLUE (cold) tie
System malfunction is indicated by three
L.E.D’s located on the top of the pump
junction box. see Figure 9.
NON RETURN VALVES MUST NOT be fitted
in the discharge pipework between the
pump outlets and the system outlets
unless specified by Salamander Pumps.
Figure 9: L.E.D. indicator
R
Salamander
Hunting Protection
Only after two hours of
persistent ON OFF ON OFF
hunting due to a dripping
(tap or shower) outlet.
Dry Run Production
Only occurs in instances of
chronic aeration or water
starvation after two ON
OFF ON OFF operation and
60 second recovery period.
(Not available on RP50TU)
Excessive Temperature
Due to the hot water
temperature exceeding
acceptable limits. The
pump will automatically
reset to operate when the
water temperature resets
to normal