4-220
E-08 Job lamps do not come on
★
Measure the voltage with the starter switch ON.
★
First, check to see if the fuse has burnt.
a) Both left and right lamps do not come on.
(SW800:To Machine No.10122 SW850: To Machine No.10126)
Which beam is
inoperative? Low
or High or both?
1
Both
3
YES
Is fault rectified if
job lamp relay is
exchanged with
head lamp relay?
• 20~28V
• Set job lamp switch
to Low.
NO
4
Is stated voltage
fed to job lamp
relay terminal 3
that carries wire
LY?
Is stated voltage
fed to job lamp
relay terminal 1
that carries wire
YB?
5
YES
NO
NO
Is stated voltage
fed to job lamp
switch terminals 1
and 4 that carry
wires RY?
• 20~28V
2
YES
NO
YES
• Set job lamp switch
to Low.
Is stated voltage
fed to job lamp
switch terminal 1
that carries wire
RY?
8
YES
NO
Is stated voltage
fed to job lamp
switch terminal 5
that carries wire
RL?
9
YES
NO
Low only
High alone
• 20~28V
• Set job lamp switch
to High.
• 20~28V
• Set job lamp switch
to Low.
• 20~28V
• Set job lamp switch
to Low.
Troubleshooting for Electric System
Содержание SW800 Series
Страница 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...SPECIFICATIONS ...
Страница 8: ......
Страница 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Страница 12: ...MEMO ...
Страница 13: ...STRUCTURE OPERATION ...
Страница 14: ......
Страница 20: ...2 006 1 4 Intake system SW850 1 Air cleaner 2 Intake hose SW8502002 2 1 1 2 Engine related Units ...
Страница 32: ...2 018 ...
Страница 68: ...INSPECTION ADJUSTMENT ...
Страница 69: ......
Страница 73: ...3 101 ...
Страница 88: ...TROUBLESHOOTING ...
Страница 89: ......
Страница 114: ...4 219 Troubleshooting for Electric System ...
Страница 134: ...4 239 Troubleshooting for Electric System ...