2-034
Vibrating System
• The amplitude select (Vibrator motor
rotating direction select) valves provide:
- High amplitude when solenoid (d) of front
valve (5) and solenoid (e) of rear valve
(6) are energized.
- Low amplitude when the opposite
solenoids are energized.
★
For operation of the solenoid valve,
see descriptions on page 2-035.
Operation of port relief valves
• Even if the amplitude select valve is
brought to the neutral position, the vibrator
shaft tends to continue rotation due to
enertia. On the other hand, there is a
shortage of oil in the feed line (line which
feeds oil to motor) of the motor, because
ports A1 and B1 are blocked.
• Then the one-way valve mounted in port
relief valve (h) on the low pressure side
opens to feed part of oil in the return line
to the motor.
• In addition, because the outlet port of the
motor stays closed, oil displaced from the
enertia-rotating motor flows into the return
line by opening the port relief valve in the
outlet circuit.
Circuit protection
* See the circuit diagram on page 2-033.
• If the system pressure rises to the setting
of relief valves (g) built in solenoid valves
(5) and (6), the relief valves open to
protect the circuit.
A
A
PF
S2
A2
A3
IN
OUT
A1
B1
A
B
T1
T1
A
B
A1
B1
T
P
P
T
9
10
7
8
5
6
h
h
d
g
i
f
e
h
h
d
g
i
f
e
4
SW8002025
From Orbitrol
Содержание SW800 Series
Страница 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...SPECIFICATIONS ...
Страница 8: ......
Страница 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Страница 12: ...MEMO ...
Страница 13: ...STRUCTURE OPERATION ...
Страница 14: ......
Страница 20: ...2 006 1 4 Intake system SW850 1 Air cleaner 2 Intake hose SW8502002 2 1 1 2 Engine related Units ...
Страница 32: ...2 018 ...
Страница 68: ...INSPECTION ADJUSTMENT ...
Страница 69: ......
Страница 73: ...3 101 ...
Страница 88: ...TROUBLESHOOTING ...
Страница 89: ......
Страница 114: ...4 219 Troubleshooting for Electric System ...
Страница 134: ...4 239 Troubleshooting for Electric System ...