4-222
Troubleshooting for Electric System
b) Eigher left or right lamp does not come on.
* Wire color codes in parentheses ( ): SW800
➡
To Machine No.10122
SW850
➡
To Machine No.10126
Codes with no parentheses
➡
Common to both models
Has filament of
bulb burnt?
1
2
YES
NO
YES
NO
• 20~28V
• Switch on job lamp
switch.
Is stated voltage
fed to job lamp (in-
operative) terminal
that carries wire RL
(O)?
Possible cause
Remedy
Repair or renew
wire.
Renew.
High beam: Wire RL from job
lamp to job lamp switch termi-
nal 5 (from branch point) not
connected or incorrectly con-
nected.
Low beam: Wire O from job
lamp to relay terminal 5 (from
branch point) not connected or
incorrectly connected.
Repair or renew
wire.
Bulb filament has burnt.
Job lamp earth wire not con-
nected or incorrectly connect-
ed.
RY
RW
O
RL
RY
RW
O
RL
Fuse
30A
SW8004007
B
B
B
O
5
3
2
1
3
LY
YB
RL
6
5
1
4
RY
RY
To instrument panel lamp
Job lamp
Job lamp switch
Job lamp relay
Job lamp
Electric wiring diagram for mode E-08
(SW800: To Machine No.10122 SW850: To Machine No.10126)
Содержание SW800 Series
Страница 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...SPECIFICATIONS ...
Страница 8: ......
Страница 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Страница 12: ...MEMO ...
Страница 13: ...STRUCTURE OPERATION ...
Страница 14: ......
Страница 20: ...2 006 1 4 Intake system SW850 1 Air cleaner 2 Intake hose SW8502002 2 1 1 2 Engine related Units ...
Страница 32: ...2 018 ...
Страница 68: ...INSPECTION ADJUSTMENT ...
Страница 69: ......
Страница 73: ...3 101 ...
Страница 88: ...TROUBLESHOOTING ...
Страница 89: ......
Страница 114: ...4 219 Troubleshooting for Electric System ...
Страница 134: ...4 239 Troubleshooting for Electric System ...