4-232
Troubleshooting for Electric System
h). AUTO mode is not selected.
(SW800: From Machine No.10123 SW850: From Machine No. 10127).
Is stated voltage
present at vibration
relay (4) terminal 5
that carries wire
Br?
1
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
2
NO
Is stated voltage
present at vibration
relay (4) terminal 3
that carries wire P?
3
YES
Is resistance of
vibration relay (4)
earth wire as
stated?
NO
10
Is stated voltage
present at battery
relay terminal BR
that carries wire
RB (BrY)?
YES
YES
NO
Is resistance of
vibration relay (4)
earth wire resist-
ance as specified?
• Lower than 1
Ω
• Disconnect relay
from wire.
4
YES
NO
Is stated voltage
present at starter
motor terminal 2
that carries wire
O?
Is stated voltage
present at starter
motor terminal 3
that carries wire
Gy?
5
YES
NO
YES
NO
YES
• 20~28V
• CONT/AUTO selector
switch: AUTO
NO
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
6
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
• 20~28V
• CONT/AUTO selector
switch: AUTO
Содержание SW800 Series
Страница 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...SPECIFICATIONS ...
Страница 8: ......
Страница 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Страница 12: ...MEMO ...
Страница 13: ...STRUCTURE OPERATION ...
Страница 14: ......
Страница 20: ...2 006 1 4 Intake system SW850 1 Air cleaner 2 Intake hose SW8502002 2 1 1 2 Engine related Units ...
Страница 32: ...2 018 ...
Страница 68: ...INSPECTION ADJUSTMENT ...
Страница 69: ......
Страница 73: ...3 101 ...
Страница 88: ...TROUBLESHOOTING ...
Страница 89: ......
Страница 114: ...4 219 Troubleshooting for Electric System ...
Страница 134: ...4 239 Troubleshooting for Electric System ...