VG5 Installation & Quick-Start Manual
89
Gr
oup E Mo
tor
To
rque C
ontro
l
E1-06
Max. Voltage
Frequency
(Base Frequency)
0.0~
400.0
0.1Hz
60.0*
(Note
13)
*Factory setting differs depend-
ing on the inverter capacity (02-
04).
When 02-09=2 (EUR.), the
value is 50.0Hz.
x Q
Q
Q Q
E1-07
Mid. Output
Frequency
(Mid Frequency A)
0.0~
400.0
0.1Hz
3.0*
(Note
13)
*Factory setting differs depend-
ing on the inverter capacity (02-
04).
When 02-09=2 (EUR.), A1-
02=0, and E1-03=OF, the value
is 5/6 times that of Japan
spec.[for a V/F pattern with a
50Hz base frequency]
x Q
Q A F
E1-08
Mid. Output
Frequency Voltage
(Mid Voltage A)
0.00~
255. 0
(Note
13)
0.1 V
11.0
(Note
13)*
*Factory setting differs depend-
ing on the inverter capacity (02-
04).
When 02-09=1 (USA), the
value is 1.15 times of Japanese
spec., which is 230/200 .
x Q
Q A F
E1-09
Min. Output
Frequency
(Min Frequency)
0.0~
400.0
0.1Hz
0.5*
(Note
13)
*Factory setting differs depend-
ing on the inverter capacity (02-
04).
When 02-09=2 (EUR.), A1-
02=0, and E1-03=OF, the value
is 5~6 times of Japan.
x Q Q Q A
E1-10
Min. Output
Frequency Voltage
(Min Voltage)
0.0~
255.0
(Note
13)
0.1V
2.0
(Note
13)*
*Factory setting differs depend-
ing on the inverter capacity (02-
04).
When 02-09=1 (USA), the
value is 1.15 times of Japanese
spec., which is 230/200.
x Q
Q A F
E1-11
Mid. Output Fre-
quency 2
(Mid Frequency B)
0.0~
400.0
0.1Hz
0.0
—
x A A A A
E1-12
Mid. Output Fre-
quency Voltage 2
(Mid Voltage B)
0.0~
255.0
(Note
13)
*
0.1V 0.0
*When 02-09=1 (USA), the
value is 1.15 times of Japanese
spec., which is 230/200.
x A A A A
E1-13
Base Voltage
(Base Voltage)
0.0~
255.0
(Note
13)
0.1V
200.0
(Note
13)
*
*When 02-09=1 (USA), the
value is 1.15 times of Japanese
spec., which is 230/200.
x A A
Q
Q
Note 13: This value is for the 200V class. For 400V class, the value is twice that of 200V class. For 575V class, then modify the values by 575/200
Function
Parameter
No.
Name
(Digital Operator
Display)
Setting
Range
Setting
Unit
Factory
Setting
Remarks
(Digital Operator Display)
Change
during
Operation
o: Enabled
x: Disabled
Parameter Access Level
User
Setting
V/f
V/f
w/
PG
Open
Loop
Vector
Flux
Vector
Appendix
VG5 Parameters
Содержание CIMR-VG5U
Страница 1: ...VG5 Series Revision F Installation Quick Start Manual General Purpose Flux Vector Inverter with AVC TM...
Страница 2: ...2 VG5 Installation Quick Start Manual This page intentionally left blank...
Страница 36: ...36 VG5 Installation Quick Start Manual This page intentionally left blank...
Страница 60: ...60 VSG5 Installation Quick Start Manual This page intentionally left blank...
Страница 113: ...VG5 Installation Quick Start Manual 113 This page intentionally left blank Appendix Notes...