GA FM 1 03.05 • 22
/
INSErTING
BaTTErY
DE-aEraTING
FluIDwaYS
(d)
The filling procedure is visible in the tank control window. The tank piston with
the yellow mark moves towards the back of the device.
The filling procedure
has to be stoped when the red mark has moved along
80% of the window.
Do not over fill the tank under any circumstances!
(e)
Pull the valve stem out of the fill opening. Put the valve protecting cap onto the
can. Prevent fill parts from getting dirty!
(f)
remove possible fluid remainders from the fill opening with a paper towel.
(SAFEX fog fluid is non-toxic and harmless.)
The insert battery is delivered with a partial charge for the initial test of the device. we
recommend to entirely charge the battery before continuous use (see also chapter „D“
MAINTENANCE AND CArE).
For optimum performance, de-aerate the fluid ways in the device after every refill.
a.
Activate and heat up the FlowMarker by pushing the white fog button for two
seconds.
b.
The heat-up takes about 30 seconds when the device is cold. After complete
heat-up
(green LED “Ready” lights up and yellow LED “Heating” goes out)
,
hold the device vertically, with its nozzle or application tube pointing up. Press
the fog button for about 45 seconds, until the fog comes out evenly.
De-aerating can only be carried out in upward direction!
a.
To place the battery in the device, first loosen
the battery
compartment safety screw
(see illustration) with a
screwdriver counter-clockwise
just one or two turns
until
the screw head corresponds with the outer surface of the
device’s housing.
Stop if there is noticeable resistance
,
do not use force,
this may damage the battery compart-
ment.
b.
Push the battery into the battery compartment (see illustra-
tion) with contacts first and inscription pointing up,
until the
battery audibly and noticeably clicks into place.
c.
Fasten now the battery securing screw by turning it clock-
wise,
again, stop if there is noticeable resistance.
This operation is necessary to prevent the battery from falling
out. By no means let the lead-acid battery fall out of the
device as it might break and corrosive acid might escape.
d.
The FlowMarker is now ready for operation and can be
activated by pressing the white multi function button (oN +
FoG) for at least 2 seconds.
The yellow lED “Heating” must
light up.
If the red lED “Battery” lightens up, the battery is empty and has to be charged
with the battery charger for at least 10 minutes. (See section „D“ MAINTENACE
AND CArE „Charging the battery”.)