  G  tecHnical Data floWMaRKeR  

OPERATION VOLTAGE 

12 Volt DC from internal battery

POWER INPUT 

3,4 A (in heating operation),  Heating power 40 w - fuse intern: 5 x 20 mm

  

- 6,3 A - medium time lag

POWER SUPPLy “INTERNATIONAL”

 

for all international voltages, with adapters for EU, GB, USA + Australia 
wall outlets, CE + Ul listed! 100 - 240 V AC / 50-60 Hz / 250 mA /18 VA 
- output: 12 V DC / 1 A / 12 VA

DIMENSIONS

 

length 210 mm without application tube, - with standard application tube 
500 mm - width 90 mm, height inclusive handle 135 mm

WEIGHT

 

2,66 kg inclusive battery and appllication tube Ar1

BATTERy

 

12 V – 2 Ah, lead-acid battery type lC-TA122PU

BATTERy CHARGING TIME

 

min. 2 hours 80% - 3 hours 100%

OPERATING TIME / BATTERy

 

for constantly switched-on device circa 2 to 5 hours, dependent on duration 
and frequency of fog generation

“SLEEP MODE” OF DEVICE

 

circa 2 minutes after last pressing fog button 

HEAT-UP TIME

 

max. 30 seconds for cold device

FOGGING MATERIAL

 

exclusively SAFEX FlowMArkEr FoG FlUID (pressurized can)

TANK VOLUME

 

circa 16 ml

FLUID CONSUMPTION

 

circa 0.7 ml/min for continuous fog generation

FOG PERFORMANCE

 

tank volume lasts for circa 20 minutes continuous fog or for about 420 fog 
cycles of circa 3 seconds each

FLUID CAN

 

pressurized can according to UN No.1950 “AEroSolS”, volume 73 ml = 
75 g, sufficient for about 2000 fog cycles of circa 3 seconds each

OPTIONAL ACCESSORy, MATERIALS, SPARE PARTS:

FOGGING MATERIAL

 

SAFEX FlowMASTEr FoG FlUID, pressurized can with 72 ml

CONDENSATION ABSORBING RINGS

 

pack. containing 10 pieces, type kr 1

 

pack. containing 10 pieces, type kr 2

SPARE FILTERS

 

pack. containing 2 filters and 2 seal rings

BATTERy CHARGER “INTERNATIONAL”

 

power supply with battery clip for external battery charging, for all inter-
national voltages, with adapters for EU, GB, USA + Australia wall outlets, 
CE + Ul listed

 

100-240 V AC / 50-60 Hz / 250 mA /18 VA - output: 12 V DC / 1 A / 12 
VA

 

power supply with battery clip for external battery charging

SPARE BATTERy

 

PANASoNIC type lC- TA 122PU, 12 V /2 Ah

APPLICATION EXTENSION TUBE

 

type Ar 2, impact resistant plastic tube with fitting, 

 

standard length 75 cm, optional up to max. 1.5 m

TRANSPORTATION CASE

 

plastic case with rigid foam compartments for safe transport of the basic 
equipment

Содержание Tintschl Engineering FlowMarker

Страница 1: ...HNE FILM FERNSEHEN G NTHER SCHAIDT SAFEX CHEMIE D 22869 SCHENEFELD BLANKENESER CHAUSSEE 26 32 TEL 040 83 92 11 0 FAX 040 830 1452 Instruction Manual Gebrauchsanleitung V 3 2 FlowMarker Flow control A...

Страница 2: ...d the safety instructions befor use Diese Gebrauchsanleitung ist zweisprachig die deutsche Version finden Sie im 2 Teil Fragen zu der Anwendung beantworten wir gerne auch per Telefon oder E Mail Die S...

Страница 3: ...ATIONS AND DESCRIPTION OF COMPONENTS S 4 5 Instruction Manual A System description 6 B Preparing device for operation 6 C Using FlowMarker 8 D Maintenance and care 9 E Storage and transportation 11 F...

Страница 4: ...ontrollampen Fill opening filter cartridge Bef ll ffnung Filterkartusche Battery compartment Batteriefach Battery compartement safety screw Batteriefachsicherung Power input socket 12 V DC Ladebuchse...

Страница 5: ...Fill opening Bef ll ffnung Pressurized can Druckgasdose Figure 4 Abb 4 Filling FLOW MARKER with FOG FLUID FLOWMARKER mit FOGFLUID bef llen Battery charger Batterie Ladeger t Fill stem F llstift Figur...

Страница 6: ...crewable application tube type AR1 one pressurized can FlowMarker Fog Fluid 4 condensation absorbing rings each type KR1 and KR2 one plastic tube for removing condensation absorbing ring KR1 a low vol...

Страница 7: ...ozzle or application tube pointing up Press the fog button for about 45 seconds until the fog comes out evenly De aerating can only be carried out in upward direction a To place the battery in the dev...

Страница 8: ...eration within few seconds depending on the time it has not been used max 30 seconds when heat exchanger has completely cooled down To use the special advantages of the patented FlowMarker the fog app...

Страница 9: ...ttery compartment safety screw hold the device upright with the nozzle showing up and slightly beat the edge of the battery compartment on the ball of the thumb of your open hand until the battery loo...

Страница 10: ...fluid channels or the heat exchanger must not be removed with acid de scaling agent or other detergents this would seriously damage the device Appropriate repairs can only be carried out at the manufa...

Страница 11: ...ce will dry up without leaving a residue In the application tube however it is likely that under intensive use the condensed fluid film will increase and fluid may drop out the tube To avoid a slide r...

Страница 12: ...CE and therefore meet to the legal regulations of the European Community The FlowMarker fulfils international standards for low voltage operated electric devices The FlowMarker contains no hazardous...

Страница 13: ...local regulations By no means open or burn the battery or short circuit the battery poles Should in case of damage any acid gel escape from the battery imme diately rinse the affected parts of the bo...

Страница 14: ...e circa 16 ml Fluid consumption circa 0 7 ml min for continuous fog generation Fog performance tank volume lasts for circa 20 minutes continuous fog or for about 420 fog cycles of circa 3 seconds each...

Страница 15: ...und Beschreibung der Bedienungselemente S 4 5 GEBRAUCHSANWEISUNG A Systembeschreibung S 16 B Ger tevorbereitung S 16 C Inbetriebnahme S 18 D Wartung und Pflege S 19 E Lagerung und Transport S 21 F Si...

Страница 16: ...ackung FlowMarker FOG FLUID Nebelmittel je 4 Kondensat Aufnahmeringen Typ KR1 und KR2 Einem Kunstoffrohr zur Entfernung des Kondensatringes KR1 einem Stecker Ladeger t 12 V 1 A 12 VA zum Laden der Bat...

Страница 17: ...ird durch ca 2 sek langes Bet tigen des wei en Knopfes aktiviert die gelbe LED HEIZUNG leuchtet dabei auf Leuchtet die rote LED Batterie auf ist die Batterie entladen und muss mind 10 Minuten mittels...

Страница 18: ...cher wieder betriebsbereit Um die besonderen Vorteile des patentierten SAFEX FLOWMARKER nutzen zu k nnen ist f r impulsarme und thermisch neutrale Nebelerzeugung das Nebel Applika tionsrohr erforderli...

Страница 19: ...lagen bis sich die Batterie l st und in die Handfl che gleitet Anschlie end gem Abschnitt B BATTERIE EINSETZEN S 17 eine frische Batterie verwenden Das Ger t ist nur f r den Betrieb mit Originalbatter...

Страница 20: ...eben werden da bereits kleinste Partikel zu einer ernsthaften reparaturaufwendigen Besch digung des Ger tes f hren k nnen Eine Verstopfung der Fl ssigkeitswege oder des W rmetauschers kann nicht mit S...

Страница 21: ...iverem Gebrauch des Ger tes wird jedoch speziell im Applikationsrohr der Niederschlag zunehmen wenn dieses nicht gut von Luft durchstr mt wird Um heraustropfendes Fluid aus dem Rohr und damit Rutschge...

Страница 22: ...isierte Werkst tten Hersteller vorgenommen werden 5 In R umen mit Publikumsverkehr sollte das Ger t f r Unbefugte nicht zugriffs bereit sein Ger t und Zubeh r Fluiddose usw geh ren ebenfalls nicht in...

Страница 23: ...s darf die Batterie ge ffnet verbrannt oder die Batteriepole kurzgeschlossen werden F r den Fall dass z B durch Bruch S uregel aus der Batterie austritt sind betroffene K rperpartien sofort mit reichl...

Страница 24: ...X FLOWMARKER NEBELFLUID Druckgasdose Tankinhalt ca 16 ml Fluidverbrauch ca 0 7 ml min bei Dauernebelerzeugung Nebelleistung Tankinhalt reicht f r ca 20 min Dauernebel oder f r ca 420 Nebelzyklen von c...

Страница 25: ...GA FM 1 03 05 22 25...

Страница 26: ...26 22 GA FM 1 05 01...

Страница 27: ...GA FM 1 03 05 22 27...

Страница 28: ...28 22 GA FM 1 05 01...

Отзывы: