  f    safetY instRUctions

GENEral

aCTIVE uSE

(Fog generation):

The nozzle of the device (see figure 2) heats up to 250°C. Do not touch during operation. 
Danger of burning! 

The discharging fog jet is hot at first (about 10 cm). 

Never direct it to persons, parti-

cularly not to the face,

 without application tube. Danger of small but hot splashes!

Allow fog to be blown towards open space. Never blow it directly on persons (minimum 
safety distance: 0.5 m). 

Do not blow fog on hot surfaces, into open flames or into glowing heating ele-
ments etc.!

The  normally  non-flammable  and  non-toxic  fog  can  decompose  on  hot,  red  glowing 
surfaces (> 380°C) or in open flames.

 

Heat sources like lamps, central heatings ore other closed heating systems or electric ma-
chines without red-glowing parts 

are no danger and need not be given attention. 

Use the FlowMarker only in dry condition; do not pour water over the device or immerse 
it in water. Any dirtying with aggressive media, dust, solvent, etc. may cause serious 
damage.

The FlowMarker is not suitable for use in explosive environment. It has no EX 
protection. Never use it in close proximity to open containers with inflammable 
liquids or in saturated areas with fumes of inflammable liquids or gases.

All SAFEX

®

-FOG GENERATORS comply  with CE  and therefore meet to the legal 

regulations  of  the  European  Community.  The  FlowMarker  fulfils  international 
standards for low voltage operated electric devices.

The FlowMarker contains 

no hazardous materials

 and only one heating element with 

circa 40 w power input. The entire power supply takes place exclusively with protective 
low voltage, provided an appropiate power transformer is used which fulfils local safety 
requirements.

Please notice:

1.  

The machines are equipped with a safety device. If the heating does not work 
properly, the machine will turn in a safe condition.

2.  

replace fuses only while machine is switched off and the failure has been cleared 
by an expert. Use only proper spare part (fuse 5 x 20 mm, type see chapter “G” 
TECHNICAl DATA on page 14).

3.  

Do not put electric machines in operation

 which may have been damaged 

by dropping or rough transport, since the safety devices may be affected even 
if there is no damage visible from the outside. In cases of doubt immediately 
disconnect the machine from power and send it in for repair.

4. 

 

Unauthorized repair or tampering with the regulation devices can lead 
to serious hazards and damage to the machine. Repairs should only be 
made by authorized service centers.

5.  

In any 

places with public admittance

 the machine must be 

out of reach for 

unauthorized

 persons. Electric installation must fulfil national safety require-

ments. keep the device, fluid can and spare parts out of children’s reach.

Содержание Tintschl Engineering FlowMarker

Страница 1: ...HNE FILM FERNSEHEN G NTHER SCHAIDT SAFEX CHEMIE D 22869 SCHENEFELD BLANKENESER CHAUSSEE 26 32 TEL 040 83 92 11 0 FAX 040 830 1452 Instruction Manual Gebrauchsanleitung V 3 2 FlowMarker Flow control A...

Страница 2: ...d the safety instructions befor use Diese Gebrauchsanleitung ist zweisprachig die deutsche Version finden Sie im 2 Teil Fragen zu der Anwendung beantworten wir gerne auch per Telefon oder E Mail Die S...

Страница 3: ...ATIONS AND DESCRIPTION OF COMPONENTS S 4 5 Instruction Manual A System description 6 B Preparing device for operation 6 C Using FlowMarker 8 D Maintenance and care 9 E Storage and transportation 11 F...

Страница 4: ...ontrollampen Fill opening filter cartridge Bef ll ffnung Filterkartusche Battery compartment Batteriefach Battery compartement safety screw Batteriefachsicherung Power input socket 12 V DC Ladebuchse...

Страница 5: ...Fill opening Bef ll ffnung Pressurized can Druckgasdose Figure 4 Abb 4 Filling FLOW MARKER with FOG FLUID FLOWMARKER mit FOGFLUID bef llen Battery charger Batterie Ladeger t Fill stem F llstift Figur...

Страница 6: ...crewable application tube type AR1 one pressurized can FlowMarker Fog Fluid 4 condensation absorbing rings each type KR1 and KR2 one plastic tube for removing condensation absorbing ring KR1 a low vol...

Страница 7: ...ozzle or application tube pointing up Press the fog button for about 45 seconds until the fog comes out evenly De aerating can only be carried out in upward direction a To place the battery in the dev...

Страница 8: ...eration within few seconds depending on the time it has not been used max 30 seconds when heat exchanger has completely cooled down To use the special advantages of the patented FlowMarker the fog app...

Страница 9: ...ttery compartment safety screw hold the device upright with the nozzle showing up and slightly beat the edge of the battery compartment on the ball of the thumb of your open hand until the battery loo...

Страница 10: ...fluid channels or the heat exchanger must not be removed with acid de scaling agent or other detergents this would seriously damage the device Appropriate repairs can only be carried out at the manufa...

Страница 11: ...ce will dry up without leaving a residue In the application tube however it is likely that under intensive use the condensed fluid film will increase and fluid may drop out the tube To avoid a slide r...

Страница 12: ...CE and therefore meet to the legal regulations of the European Community The FlowMarker fulfils international standards for low voltage operated electric devices The FlowMarker contains no hazardous...

Страница 13: ...local regulations By no means open or burn the battery or short circuit the battery poles Should in case of damage any acid gel escape from the battery imme diately rinse the affected parts of the bo...

Страница 14: ...e circa 16 ml Fluid consumption circa 0 7 ml min for continuous fog generation Fog performance tank volume lasts for circa 20 minutes continuous fog or for about 420 fog cycles of circa 3 seconds each...

Страница 15: ...und Beschreibung der Bedienungselemente S 4 5 GEBRAUCHSANWEISUNG A Systembeschreibung S 16 B Ger tevorbereitung S 16 C Inbetriebnahme S 18 D Wartung und Pflege S 19 E Lagerung und Transport S 21 F Si...

Страница 16: ...ackung FlowMarker FOG FLUID Nebelmittel je 4 Kondensat Aufnahmeringen Typ KR1 und KR2 Einem Kunstoffrohr zur Entfernung des Kondensatringes KR1 einem Stecker Ladeger t 12 V 1 A 12 VA zum Laden der Bat...

Страница 17: ...ird durch ca 2 sek langes Bet tigen des wei en Knopfes aktiviert die gelbe LED HEIZUNG leuchtet dabei auf Leuchtet die rote LED Batterie auf ist die Batterie entladen und muss mind 10 Minuten mittels...

Страница 18: ...cher wieder betriebsbereit Um die besonderen Vorteile des patentierten SAFEX FLOWMARKER nutzen zu k nnen ist f r impulsarme und thermisch neutrale Nebelerzeugung das Nebel Applika tionsrohr erforderli...

Страница 19: ...lagen bis sich die Batterie l st und in die Handfl che gleitet Anschlie end gem Abschnitt B BATTERIE EINSETZEN S 17 eine frische Batterie verwenden Das Ger t ist nur f r den Betrieb mit Originalbatter...

Страница 20: ...eben werden da bereits kleinste Partikel zu einer ernsthaften reparaturaufwendigen Besch digung des Ger tes f hren k nnen Eine Verstopfung der Fl ssigkeitswege oder des W rmetauschers kann nicht mit S...

Страница 21: ...iverem Gebrauch des Ger tes wird jedoch speziell im Applikationsrohr der Niederschlag zunehmen wenn dieses nicht gut von Luft durchstr mt wird Um heraustropfendes Fluid aus dem Rohr und damit Rutschge...

Страница 22: ...isierte Werkst tten Hersteller vorgenommen werden 5 In R umen mit Publikumsverkehr sollte das Ger t f r Unbefugte nicht zugriffs bereit sein Ger t und Zubeh r Fluiddose usw geh ren ebenfalls nicht in...

Страница 23: ...s darf die Batterie ge ffnet verbrannt oder die Batteriepole kurzgeschlossen werden F r den Fall dass z B durch Bruch S uregel aus der Batterie austritt sind betroffene K rperpartien sofort mit reichl...

Страница 24: ...X FLOWMARKER NEBELFLUID Druckgasdose Tankinhalt ca 16 ml Fluidverbrauch ca 0 7 ml min bei Dauernebelerzeugung Nebelleistung Tankinhalt reicht f r ca 20 min Dauernebel oder f r ca 420 Nebelzyklen von c...

Страница 25: ...GA FM 1 03 05 22 25...

Страница 26: ...26 22 GA FM 1 05 01...

Страница 27: ...GA FM 1 03 05 22 27...

Страница 28: ...28 22 GA FM 1 05 01...

Отзывы: