SAFEGREASE, SAFEOIL, MULTILUBE
ST-1440
14402BEN.doc
12.11.2004 Rev. 2B
8 (19)
Display lines
Note
The texts in brackets are sample display texts.
The first line indicates the selected channel
•
number
(
CH12
)
•
operation mode (
SG2
)
•
name
(
Machine 1
)
The second line indicates
•
either the pressure levels at the pressure transmitter channel (
L1:118bar L2:005bar
)
•
or the pressure switch channel switch status (
PS1 close PS2 open
)
The third line indicates the selected channel
•
line control (
L1on
)
•
pump control (
ON/S
)
•
elapsed pumping time (
00025s
)
The fourth line indicates
•
the function key texts
Display function keys
Key Description
Line
Line control (
Off
/
L1on
/
L2on
)
Press key to switch line control on.
Off
: no line controls
L1on
: line control for line 1
L2on
: line control for line 2
Note
In dual-line MultiLube –system ML2 pressure from line 2
discharges by switching on line control
L1on
.
Pump
Pump control (
Off
/
ON/S
/
ON/F
)
Press key to start and stop the pump.
Off
: pump is stopped / not operating
ON/S
: pump is running on switch control
ON/F
: pump is running on forced control
Note
Oil lubrication system can use only forced control.
Note
The pump does not start, if line control is not switched on.
Esc
Back to basic display