SAFEGREASE, SAFEOIL, MULTILUBE
ST-1440
14402BEN.doc
12.11.2004 Rev. 2B
9 (19)
Switch control
•
in the pressure switch channel the pump stops when the pressure switch is closed and re-
starts when the switch is re-opened
•
in the pressure transmitter channel the pump is stopped when pressure exceeds the set
high limit and is re-started when pressure goes below the high limit value
Forced control
•
pump operates on forced control without any pressure control
Pumping time
•
Pumping time always starts at zero status, when pump is started.
•
When switch control is being used, time value is not reset, although pressure control unit
stops and starts the pump
3.4 Lubrication cycle counter
Channel lubrication cycle counter is displayed by selecting
Page
-
Othr
-
Cntr
at the basic
display.
CH12 SG2 Machine 1
lub. counter 00015
cleared 14.05.97
Chnl ---- Clr Esc
Figure 6.
Lubrication cycle counter display
Display lines
Note
The texts in brackets are sample display texts.
The first line indicates the selected channel
•
number
(
CH12
)
•
operation mode (
SG2
)
•
name
(
Machine 1
)
The second line indicates the selected channel
•
lubrication cycle count (
lub. counter 00015
)
The third line indicates the selected channel
•
the last date when the counter was cleared (
cleared 14.05.97
)
The fourth line indicates
•
the function key texts