SAFEGREASE, SAFEOIL, MULTILUBE
ST-1440
14402BEN.doc
12.11.2004 Rev. 2B
18 (19)
5 TECHNICAL SPECIFICATION
5.1 Technical specifications
Quantity Range
Unit
Description
t 0…+60
°C
operation
temperature
U
in
230 ±15%, 50/60
115 ±15%, 50/60
V AC, Hz
V AC, Hz
Power input, 250 W max.
Voltage area selection within the power supply
Voltage range preset at factory and indicated
in the center name plate.
U
out
24
V DC
Control voltage, regulated 10 A max.
The internal power supply for controlling the
system.
F 6
A Automatic
fuse
600 x 600 x 210
(w x h x d)
mm Steel
enclosure
IP55
Protection
classification
Time settings
Channel-specific lubrication cycle can be set within 1 min - 999 h 59 min.
Channel-specific maximum pressurization time can be set within 0 s - 9999 s.
All time settings are password-protected.
Power failure protection
The set values and configuration settings stored in the EEPROM-memory do not require a
back-up battery protection. Program status and lubrication history data are protected by a back-
up battery.