Display function keys 

Key Description 

Chnl

 Channel 

selection 

Press key to display the configuration settings for the next channel. 
Channel can also be selected with 

Í

 and 

Î

 keys, which can used for toggling 

between channel up and down. 

Set

 Configuration 

mode 

Press key to go into configuration settings mode in which you can change the 
configuration settings for the selected channel. The program requires a separate 
password before it accepts this command. 

Esc

 

Back to basic display 
Press key to return to the basic display. 

Configuration settings 

 

Note 

Configuration settings should be changed only when changes are made to 
the system, for example, additional channels and pumping centers are 
installed. These changes are usually implemented by the supplier. 
Configuration mode requires a password 

1341 

or

 1441

 

Each channel can be set to different operation modes regardless of the settings of the other 
channel. 

Display code 

Selected operation mode 

SG1 

Single line grease lubrication channel 

SG2 

Dual line grease lubrication channel 

SG2E 

Dual line grease lubrication channel, 

 

pressurization maintaining operation 

OS 

oil lubrication channel 

ML1 

Single line MultiLube 

ML2 Dual 

line 

MultiLube 

 

In ST-1340 control center all channels are in group 1. 

Channel line and pump control are switched on at the set pump control channel. 

The channel-specific alarm relay can be set as alarm (

Relay 0

) or status output (

Relay 1

). 

The pressure control unit can selected to be pressure transmitter (

P-transm.

) or pressure 

switch (

P-switch

). 

The center specific configuration settings include 

 display 

language 

 date 

and 

time 

 

delay multiplier, factory setting = 3 

 pressure 

unit 

Содержание ST-1340

Страница 1: ...brication 7 3 3 Manual operation 7 3 4 Lubrication cycle counter 9 3 5 Power failure 10 3 6 Alarms 10 3 6 1 Low level alarm 10 3 6 2 Pressure alarm 11 3 6 3 Power failure alarm 11 3 6 4 Error alarm fr...

Страница 2: ...rawing 461838A ST 1340 control center main switch pos 1 is located on the side of the center enclosure The enclosure cover has a green LED signal for power pos 2 and a red LED signal for alarm pos 3 C...

Страница 3: ...nnel input via a serial bus interface A designated channel number has been preprogrammed for each module and the number is also printed on the module cover The programming switch PR RN for a channel m...

Страница 4: ...e LED signal is lit when extra lubrication is applied not included in standard delivery L1 L2 Line controls The LED signal is lit when control is switched on SV Shut off valve control The LED signal i...

Страница 5: ...the channel automatically if the keypad has been used during the past five 5 minutes or if the center is in alarm mode 3 1 1 Basic display CH2 SG2 Machine 1 Interval 012h10min L1 005bar L2 005bar Chnl...

Страница 6: ...example if the channel is in alarm mode one of the function keys acts as an alarm reset key Display function keys Key Description Chnl Channel selection Press key to go to next channel Channel can als...

Страница 7: ...nnel is closed maximum pressurization time 0 Closed status duration Channel module error An error in the communication between channel module and CPU unit or in channel module power input will also tr...

Страница 8: ...een pressurization phases A phase code Delay and the remaining delay time are displayed The second pressurization phase in pressure transmitter channel is started when the pressure in the lines drops...

Страница 9: ...sed pumping time 00025s The fourth line indicates the function key texts Display function keys Key Description Line Line control Off L1on L2on Press key to switch line control on Off no line controls...

Страница 10: ...ontrol is being used time value is not reset although pressure control unit stops and starts the pump 3 4 Lubrication cycle counter Channel lubrication cycle counter is displayed by selecting Page Oth...

Страница 11: ...lit Channel specific alarms are visible in channel module AL LED signals and in the channel basic displays Press the Ack key for the channel in question to reset the alarm Note The alarm can be reset...

Страница 12: ...he same line will be pressurized again when the alarm has been reset by pressing the Ack key for the channel in question Pressure transmitter operation In pressure transmitter operation pressure alarm...

Страница 13: ...rm relay The red Alarm LED signal on the center cover shows the status of the center specific alarm relay with the exception of the case when the center is potential free The alarm relay is in alarm m...

Страница 14: ...exts in brackets are sample display texts The first line indicates the selected channel number CH2 operation mode SG2 name Machine 1 The second line indicates the selected channel set lubrication cycl...

Страница 15: ...this command Esc Back to basic display 4 3 Settings mode The settings for the selected channel can be displayed by selecting Page Set at basic display The program requires a password before it accepts...

Страница 16: ...he first line indicates the selected channel number CH2 operation mode SG2 name Machine 1 The second line indicates the selected channel set lubrication cycle Tc 024h00min set maximum pressurization t...

Страница 17: ...t within 0 160 bar The pressure low limit can be set between 0 bar and the set pressure high limit 4 5 Configuration display Channel configuration settings are displayed by selecting Page Othr Conf at...

Страница 18: ...are installed These changes are usually implemented by the supplier Configuration mode requires a password 1341 or 1441 Each channel can be set to different operation modes regardless of the settings...

Страница 19: ...g the system F 6 A Automatic fuse 600 x 380 x 210 w x h x d mm Steel enclosure IP55 Protection classification Time settings Channel specific lubrication cycle can be set within 1 min 999 h 59 min Chan...

Страница 20: ...to be lubricated in operation switch open Extra lubrication Outputs channel Line 2 pcs channel changeover contact 24V 2A max Pump control changeover contact 24V 2A max shut off valve control changeov...

Страница 21: ......

Страница 22: ......

Отзывы: