SAFEGREASE, SAFEOIL, MULTILUBE
ST-1340
13401BEN.doc
27.12.2004 Rev. 1B
18 (19)
5 TECHNICAL SPECIFICATION
5.1 Technical specifications
Quanti
ty
Range Unit
Description
t 0…+60
°C Operation
temperature
U
in
100…240, 50/60
V AC, Hz
Power input, 150 W max.
U
out
24
V DC
Control voltage, regulated 5 A max.
The internal power supply for controlling the
system.
F 6
A
Automatic
fuse
600 x 380 x 210
(w x h x d)
mm Steel
enclosure
IP55
Protection
classification
Time settings
Channel-specific lubrication cycle can be set within 1 min - 999 h 59 min.
Channel-specific maximum pressurization time can be set within 0 s - 9999 s.
All time settings are password-protected.
Power failure protection
The set values and configuration settings stored in the EEPROM-memory do not require a
back-up battery protection. Program status and lubrication history data are protected by a back-
up battery.