(Applicable only if ATEX option is ordered)
ATEX DIRECTIVE
•
This product complies with the ATEX Category as stated on the ATEX system label shown below.
•
A static hazard may exist – Do not clean non-metallic parts with a dry cloth.
•
Ensure torque setting on fixings highlighted below conform to the values stated on page 5 “Technical
Specification”.
•
Do not open any electrical enclosures when product is energized or when an explosive dust atmosphere is
present.
•
Regular inspection of plastic and gasket materials should be made to ensure no wear or damage has occurred
that may affect the ingress integrity of the system.
•
The power supply/module enclosure can in some cases accommodate additional glands that can be fitted by
the end user. If new glands or blanking plugs are fitted by the end user they must ensure that the fitting are of
metal construction and that the ingress integrity of the enclosure is maintained. (Must be sealed to IP6X or
better).
Module cover
fixing bolts
Power supply lid
fixing bolts
Module cover
and power supply
lid fixing bolts
Endplate fixing
bolts torque 4Nm
Position of EX Label ~
See over for more
details