Page 12
THE DISPLAY
AND TOUCH KEY FUNCTIONS
Liquid Crystal Display (LCD)
Used to display the information in the metal
detector’s computer.
Bar Graph Display
Displays the level/amplitude of signals
generated in the detector head.
If
green the
signal is below the level required to trigger
the metal detector. When red the signal is in
excess of the level required to trigger the
output signal.
Detect
A red LED indicates that the output has been
triggered.
Prog/Exit
Used to enter or exit the metal detectors
com- puter programme
Recall
Used to step back to the previous page in
the menu system (see using the page
display menu system)
Cursor Move Key
Used to control the movement of the cursor
when entering a digital value.
Up/down key
Used to increase or decrease a digital value.
Enter
Transfers data from the display and enters it
into the computers memory.
Soft keys
Controlled by the software the function of
these keys will vary dependent upon the
page display.
OPERATING
AND ACCESS MODES
Running Mode
This represents the normal running display of
the metal detector. In this mode information
may be observed but the display values
cannot be changed.
By pressing the RECALL key the user may
observe the following settings:
Serial No #4W# – Metal detector head serial
number.
M/C Model ### - The least significant digit
indicates the module stagger frequency.
The centre digit indicates the metal detector
head frequency.
The most significant digit indicates the metal
detector head memory size.
Ver #.## - Metal detector module Firmware
issue/version.
By pressing the ETC soft key the user may
observe the following settings:
Pack count
########
Reject count ####
Current time ##.##
Next QA test
##.## -
If selected
Operator Access Mode
The operator may change the following
parame- ters
Product Number (Prod No ##)
Sensitivity settings (Sens4##)*
* Access may be full or limited set from the
engineers mode. If set to limited, sensitivity
cannot be adjusted.
Содержание STANDARD SERIES
Страница 11: ......
Страница 22: ...Figure 6C Cable Gland Assemblies for Power Supply Unit Page 9A...
Страница 23: ...Figure 8 Bearing Block Insulation Figure 7 Roller Shaft Insulation one end only Page 9B...
Страница 24: ...THIS PAGE IS LEFT BLANK INTENTIONALLY Page 9C...
Страница 25: ...Page 10...
Страница 26: ......
Страница 78: ...Page 60 TYPICAL METAL DETECTOR CONVEYOR...