Page 37
PRINT-OUTS / DATA COLLECTION
Information (or data) being transmitted by the metal
detector may be transferred directly to paper by using a
local printer unit (LPU). Alternatively it may be collected
by other types of ’intelligent’ equipment.
The following description assumes that a LPU is being
used to obtain a ’hard copy’ print out of information
available from the metal detector.
For this facility to work the ’Printer – YES/NO’ option in
the QA Inspector setup mode must be selected.
See Appendix D for ’Sample Printed Reports Showing
Format And Contents’.
Connection of the LPU is to COM1 on the metal detector
power supply unit. See Appendix C for ’Setting ’Up And
Connecting A Printer To The Metal Detector’.
Shift Report printout
Depending on how the QA Inspector has setup the PVR
the shift report printout may include all reject relay
operations and/or modified settings or no shift information
at all.
Once a shift report has been printed the metal detector
starts to accumulate information for the next shift and the
previous shift report is abandoned.
The shift report is printed under any one of the following
three condition;
1) On a timed basis – see under ’Configuring The PVR’
the ’Shift Report Interval’,
2) When selected in the QA Inspector mode.
a) Enter QA Inspector access code.
b) Press ’PRINT’ soft l<ey the display reads.
PRINT ALL SETTINGS
PRINT SHIFT REPORT
c) Select PRINT SHIFT REPORT.
c) If nothing further is required press the PROG/ EXIT
key to return to the running mode.
3) If the accumulated shift report information exceeds the
available storage space. This is not likely to happen
under normal operating conditions.
Settings printout
This printout contains all the Engineer and QA settings.
1) Enter QA Inspector access code.
2) Press ’PRINT’ soft key the display reads.
PRINT ALL SETTINGS PRINT SHIFT REPORT
3) Setect PRINT ALL SETTINGS.
3) If nothing further is required press the PROG/ EXIT
key to return to the running mode.
Performance Check printout
As detailed in The Performance Validation Rou- tine
section above, printouts are immediate when a
performance check is carried out.
Printer Error Messages
There are currently two error messages associated with
the printer / data collection unit, these are:-
1) DATA COLLECTION UNIT NOT READY
This occurs if the module can not communicate with the
printer,
Check –
a) is the printer powered up?
b) is the printer set up correctly (see Appendix C for
’Requirements Of Your Serial Printer’) ?
c) is the wiring and connections from the metal detector
to the printer correct
’?
d) has the printer paper run out or the paper jammed?
e) is the printer ’on line’?
2) DATA COLLECTION UNIT NOT CONFIGURED
This occurs if the printer is not configured in, either by the
supplier, or by the customer from within the QA Inspector
mode.
This will only occur following an attempt to drive the
printer from the QA Inspector mode.
Содержание STANDARD SERIES
Страница 11: ......
Страница 22: ...Figure 6C Cable Gland Assemblies for Power Supply Unit Page 9A...
Страница 23: ...Figure 8 Bearing Block Insulation Figure 7 Roller Shaft Insulation one end only Page 9B...
Страница 24: ...THIS PAGE IS LEFT BLANK INTENTIONALLY Page 9C...
Страница 25: ...Page 10...
Страница 26: ......
Страница 78: ...Page 60 TYPICAL METAL DETECTOR CONVEYOR...