5. SERVICE PROGRAMME
ROYAL
Page 20/24
REV.4 SEPT.2003
Saeco International Group
Function
Setting range
Increment
Comments
TOTAL WATER....S2
(ml) Number
Pump system 2
Total water flow volume (in ml) /
not resettable
WATER DESCALING
S2
(ml)
Pump system 2:
Total water flow (in ml) since last
descaling.
Reset: See S1
HOT WATER
FLOW (l/h) 20
6 – 34 1/h
+/- 2 1/h
The pump delivery rate for hot
water can be expressed in litres per
hour.
HEISSWASSER---
PUMPENREG 63000
58,000 - 65,500
+/- 1
The pump delivery rate is adjusted
in relation to the HOT WATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under HOT WATER PUMP
ADJUSTMENT.
WATER RESERVE
NUMBER
No. of PULSES
1000
From Version: 2003
1-2500
Counts the pulses programmed
under water reserve stop from
when the reed switch switches.
The indicator signalling the need
to fill the water tank then appears.
WATER RES. STOP
No. of PULSES
NUMBER
From Version: 2003
1-2500
Number of residual pulses from
when the reed switch switches to
when the water low indicator
appears. (can be changed)
TURBO FACTOR
10 - 250
Conversion factor for pressure-
resistant flow meter.
(Setting value for Roy. Profess.:
100
(Setting value for Roy. Coffeebar:
77
MACHINE STATUS
100
0 - 255
Operating status
--DATE OF MANUF---
DAY
---------------------
------------------
-----
--DATE OF MANUF---
MONTH
---------------------
------------------
-----
--DATE OF MANUF---
YEAR
---------------------
------------------
-----
This date indicates when the
machine was manufactured. This
date cannot be changed.
--SERVICE DATE--
DAY
0 - 31
+/- 1
--SERVICE DATE--
MONTH
0 - 12
+/- 1
--SERVICE DATE--
YEAR
1996 - 2050
+/- 1
The service date indicates the date
of the machine's last service. This
date can be changed and must be
updated at each service.
Exit:
Switch the machine off at the main switch.
Содержание Cappuccino
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 16: ......
Страница 18: ......
Страница 44: ......
Страница 46: ......
Страница 70: ......
Страница 95: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 6 FAULTS Page 1 Faults 1...
Страница 96: ......
Страница 100: ......
Страница 102: ......
Страница 116: ......
Страница 120: ......
Страница 141: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 10 CIRCUIT DIAGRAMS...
Страница 142: ......
Страница 143: ......