5.2. Diagnosis menu
(Royal Office)
The values below can be read and adjusted in the diagnosis menu as shown in the table.
Access:
Access the user menu (Keep the C + hot water button pressed and turn machine on from
main switch).
Enter code: 111111 = Press the expresso button six times.
Using the
button scroll to the menu item "Diagnosis" and confirm with the E = Expresso button.
Changing programme values:
Access appropriate item using the E-button.
Change value with ARROW buttons
Save value by using the E-button.
Programme table
(diagnosis menu)
Function/Standard
Setting range
Increment
Comments
EXPRESSO
No. of PULSES 195
50 - 800 Pulses
+/- 1
COFFEE
No. of PULSES 360
50 - 800 Pulses
+/- 1
Number of flow meter pulses for
each saved cup fill volume, where
300 pulses correspond to approx.
100 ml.
HOT WATER
No. of PULSES 360
50 - 800 Pulses
+/- 1
Saved pulse number for hot water
quantity programme
----HEATING----
PARAMETER K1 7
1 – 50
+/- 1
Do not change!
----HEATING----
PARAMETER K2 40
1 – 50
+/- 1
Do not change!
NORMAL TEMP.
° C 86
70- 130°C
+/- 1
Normal temperature is used if not
more than 6 min. have elapsed since
last coffee dispensed.
HIGH TEMP.
°C 92
70- 130°C
+/- 1
If no coffee is dispensed for an
extended time (over 6 min.), the
next coffee will be heated to a
higher temperature to compensate
for cooling of the brewing unit and
the associated temperature loss.
TEMP. OF 1st COFFEE
° C 94
70- 130°C
+/- 1
Used when dispensing the first
coffee after the machine has been
turned on, to compensate for the
high temperature loss due to the
cold brewing unit and water pipes.
TEMP. INCREASE
°C 10
0-50°C
+/-1
The boiler temperature is increased
by a set value shortly before
brewing in order to pre-heat the
boiler. and compensate for the
temperature drop during the first
water flow.
Содержание Cappuccino
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 16: ......
Страница 18: ......
Страница 44: ......
Страница 46: ......
Страница 70: ......
Страница 95: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 6 FAULTS Page 1 Faults 1...
Страница 96: ......
Страница 100: ......
Страница 102: ......
Страница 116: ......
Страница 120: ......
Страница 141: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 10 CIRCUIT DIAGRAMS...
Страница 142: ......
Страница 143: ......