CHS100.86.011 Rev.02 Date 23/07/2018
33
OPERATOR MESSAGES
3001 CAP REQUEST WAIT (KA307) (MESSAGE)
The cap request input KA307 is off during the automatic cycle.
The machine switches over the stand-by.
3002 TRIGGER PULSE WAIT FROM CVS VISION SYSTEM (MESSAGE)
The vision system is not inspecting. Check the CVS settings and data items.
The machine switches over the stand-by.
3003 OVERTEMPERATURE INSIDE CABINET (ST113) (MESSAGE)
The temperature inside the CHS cabinet is higher than the threshold set for thermostat
ST113.
Make sure air conditioner EV113 works efficiently.
Make certain thermostat ST113 is properly set and works efficiently.
3004 CHECK CAP OUTFEED IN THE OVERTURNED CONVEYOR BELT (SQ11B)
(MESSAGE)
Photocell SQ11B is continuously active.
Remove the caps from the conveyor before restarting the automatic cycle.
3005 CHECK CAP INFEED IN THE FIRST CONVEYOR BELT (SQ53) (MESSAGE)
Photocell SQ53 is continuously active.
Remove the caps from the conveyor before restarting the automatic cycle.
3006 CHECK CAP INFEED IN THE OVERTURNED CONVEYOR BELT (SQ53B)
(MESSAGE)
Photocell SQ53B is continuously active.
Remove the caps from the conveyor before restarting the automatic cycle.
3007 CHECK CAP OUTFEED IN THE FIRST CONVEYOR BELT (SQ11) (MESSAGE)
Photocell SQ11 is continuously active.
Remove the caps from the conveyor before restarting the automatic cycle.
3008 CAP FEED LINE NOT READY (OKR3M) (MESSAGE)
The line did not provide the trigger pulse signal in automatic mode.
Input OKR3 is open; this input must be closed so as to start the line in automatic mode.
3009 FEED CHANNEL EMPTY (SQ2) (MESSAGE)
The feed channel is empty. Photocell SQ2 does not detect any cap.
The machine switches over the stand-by.
Make certain there are no mechanical obstructions that prevent the caps from moving
forward along the feed channel.
Make sure photocell SQ2 is properly secured and set.