CHS100.86.011 Rev.02 Date 23/07/2018
18
- OPTIONAL SPARK TESTER DATA MENU (if present)
Number of SPARK TESTER
: the number of machine rejects for defects due to the micro-
holes are counted.
YV30 reject tolerance
: the number of tolerance caps that will be rejected when one cap is
rejected. If the data item is set to 1, 3 caps will be rejected: the defective cap, the previous
cap and the next cap. Set this value to 1 or to a greater value.
Distance between YV3 and SPARK TESTER
: the number of caps between the feed
cylinder (YV3) and the high voltage electrode of the Spark tester is set.
Distance between YV3 and YV30
: the number of caps between the feed cylinder (YV3)
and the reject valve (YV30) is set.
Distance between YV3 and SQ11
: the number of caps between the feed cylinder (YV3)
and the count photocell (SQ11) is set.
Reject blow duration (YV30)
: the activation time of the blow for reject (YV30) is set,
expressed in milliseconds.