CHS100.86.011 Rev.02 Date 23/07/2018
20
- MACHINE SETUP MENU
CHS model (CHS100 or CHS200)
: enter either 100 or 200 to activate the set-up for CHS100
or CHS200 respectively.
Type of cap timing device (1=starwheel, 2=double roller)
: enter either 1 or 2 to activate
the set-up for a starwheel timing device or a double roller timing device respectively.
Motor M13 rated speed:
enter the number of rated revs/min, referred to the cap timing
motor.
Motor M13 gearbox
: enter the value of the reduction ratio for the gearbox referred to the
cap timing device.
Inverter M13 maximum frequency:
enter the maximum frequency value for the inverter in
the cap timing device.
Number of cavities, Starwheel M13:
enter the number of cavities found in the feed
starwheel.