K-ROTOLIFT RF + AUTOLID
30
AUTOLID electric motor overload
Lower the Autolid load ( lid too heavy)
LIFTs wiring disconnected
Check all the connections and contacts from LIFT
wiring to control box. Some pins might be loose
due to transport of furniture fitting.
AUTOLID's wiring
disconnected
Check all the connections and contacts from
AUTOLID wiring to control box. Some pins might
be loose due to transport of furniture fitting
Rotating movement stopped
due to safety
Remove obstacles from the lifts way.
Central
„0” position acquired
-------
No impulses from LIFT's Motor
The LIFT motor might be blocked mechanically ,
unable to start moving. Cables might be loose.
Many reasons to this error
– please contact
Sabaj support, providing photos of the
installation.
No impulses from LID's Motor
The LID motor might be blocked mechanically,
unable to start moving. Cables might be loose.
Many reasons to this error
– please contact
Sabaj support, providing photos of the
installation.
Full motion reset
-------
Assign IR remote to control box
Press I,II, III, IV, V consequently to program