Mounting Page
10
Document id: 7000 108-011 A2
2.4 Pilot
Plug
The pilot plug, for connecting the Personal Pilot Unit(PPU), is
located on the front of the R4 Display, see Figure 3.
The installer may choose to install a separate pilot plug so that a pilot
can connect a Personal Pilot Unit (PPU). This pilot plug should be
connected in parallel with the R4 Display pilot plug. Use the
following plug (or physical and electrical equivalent plug):
Item Type
Manufacturer Part
number
1
Receptacle, shell size
11, 9 pin std
AMP
206486-1, Square Flanged
1.1 Receptacle, alternative
AMP
206486-2, Free Hanging
2
Contact pin (5 pcs
used)
AMP
66570-3, solder type
Pin Connection
1 Transmit
A
4 Transmit
B
5 Receive
A
6 Receive
B
9 Shield
(GND)