11
NON-ALARM CONDITIONS
HELLO, SAFE START-UP
When power is applied to the Digital Gateway the door
will not move regardless of the status of any activator.
The display will read HELLO. The system will reset
and be operational with any activator change or if the
Digital Gateway is reset with the Open Jog/Reset
button or Stop input (Figure13).
HELLO
A0500029
Figure 13
EdGE, REVERSING EDGE TRIPPED
The message EdGE will be displayed if the door
comes down on something activating the reversing
edge. The door will reverse to the open position. To
reset the system and close the door use the PB1, A/A,
or Close input. To reset the system and leave the door
open use the Open Jog/Reset button or the Stop input.
(See Figure 14.)
EdGE
A0500029
Figure 14
LOC, IDLE STATE
This message will be displayed when input 24 is
activated, the door is fully closed (on the "Close" limit
switch) and the Digital Gateway programmed for LOC.
The Digital Gateway will be inactive and no inputs will
operate the door. (See Figure 15).
LOC
A0500029
Figure 15
NON-ALARM CONDITIONS