10
AJAr, BREAKAWAY KILL SWITCH
This alarm tells you the bottom bar on the door has
been broken away. The display message AJAr and the
LSB LED will blink. Reassemble the bottom bar and
reset the Digital Gateway. (See Figure 10.)
A0500029
AJAr
Figure 10
OLr, OVERLOAD RELAY
This alarm indicates that the overload relay in the
control box has tripped. The display message OLr will
blink and the OLR LED will be on. Find the problem
that caused the overload relay to trip, reset the over-
load relay and reset the Digital Gateway. (See Figure
11.)
OLr
A0500029
Figure 11
EdGE, REVERSING EDGE
This alarm indicates that the reversing edge connec-
tion (input 17) is missing. The Digital Gateway moni-
tors the connection every time the door is fully open. If
the connection is missing for 2 seconds or more, the
door will remain open, the display message EdGE,
and the RE input LED will blink. Reconnect the input
and reset the Digital Gateway. (See Figure12.)
The message EdGE will be displayed, but will not blink
if the door came down on something activating the
reversing edge. The door will then reverse to the open
position. The display will show EdGE like Figure 12,
but the LED will be off.
A0500029
EdGE
Figure 12
ALARM CONDITIONS