7
TIMERS
A/A Close Delay Timer—
ON/OFF Button
A0500029
OPEN Backup Timer
CLOSE Backup Timer
Auto Close
Timer
A/A
Close
Delay
Timer
Figure 4
NOTE: The timers have a range of 0–99 seconds.
They will count down from the set value to
0 in 1-second intervals. The factory default
setting for each timer is one second.
OPEN BACKUP TIMER
This is the backup timer for the opening of the door.
This timer will stop the door if it does not reach the
open limit switch in the time set. When the time has
been exceeded the display message OP = 0 and the
LSO LED will blink until the system has been reset.
To reset the system:
Determine the reason the door
did not reach the limit switch and correct the problem.
Then reset the Digital Gateway by pressing the Open
Jog/Reset button or Stop button.
This timer should be set 1–2 seconds longer than it
takes the door to open. It will count down as the door
is opening. Settings and messages for this timer will
be displayed as "OP =" plus time.
CLOSE BACKUP TIMER
This is the backup timer for the closing of the door. It
functions the same as the open backup timer. When
the time has been exceeded the display message
CL = 0 and the LSO LED will blink until the system has
been reset. This timer should be set 1–2 seconds
longer than it takes the door to close. Settings and
messages for this timer will be displayed as "CL ="
plus time.
ALTERNATE ACTION (A/A) CLOSE DELAY TIMER
This timer delays the closing of the door when it is
opened by an A/A activator or PB1 (terminal 11 or 12).
After the A/A or PB1 connection is removed and the
door has reached the open limit switch, the timer will
time out and close the door.
For no closing delay set the timer to 0. Settings and
messages for this timer will be displayed as "ACL="
plus time.
The use of this timer is optional. It is turned on with the
A/A Close Delay Option button. The LED above the
button will be on when the timer is on. To operate the
door manually with the A/A or PB1 connection this
timer should be off (Figure 5).
A/A Close Delay Timer
Set For 2 Seconds
A/A Close
Delay Option
LED "ON"
A0500029
ACL= 2
Figure 5