Russound RFR-E5 Installation Manual

The lightning flash with arrowhead symbol, within an equilateral triangle, 

is  intended  to  alert  the  user  to  the  presence  of  uninsulated  “dangerous 
voltage” within the product’s enclosure that may be of sufficient magnitude 
to constitute a risk of electric shock to persons.

The  exclamation  point  within  an  equilateral  triangle  is  intended  to  alert 

the user to the presence of important operating and maintenance (servicing) 
instructions in the literature accompanying the appliance.

Safety Instructions:

For  your  safety,  please  read  and  follow  these  precautions 

before installing or using this product:

Read  instructions.  Read  and  understand  the  applicable 

1. 

instructions before installing or operating the product.
Retain instructions. Keep this manual in a convenient place 

2. 

for reference.
Heed  warnings.  Be  aware  and  heed  all  warnings  on  the 

3. 

product and in the instructions.
Follow  instructions.  Install  and  use  this  product  only  as 

4. 

described in the instructions. Don’t try to use this product 
in ways it wasn’t designed for.
Use indoors only. Don’t expose this product to the weather 

5. 

or  harsh  environmental  conditions  such  as  continuous 
sunlight, excessive humidity, or rain.
Keep product dry. Don’t use the product near water; e.g., 

6. 

near a bathtub, washbowl, kitchen sink, laundry tub, in a 
wet basement, or near a swimming pool. Do not handle the 
product when hands are wet or damp.
Avoid  heat.  Locate  the  product  away  from  heat  sources 

7. 

such as radiators, heat registers, stoves or other appliances 
(including amplifiers) that produce heat.
Use  the  right  power  source.  Don’t  connect  the  product 

8. 

directly  to  electrical  line  voltage.  Use  only  the  power 
adapter  provided  with  the  product,  described  in  the 
operating instructions, or as marked on the product.
Ground product properly. Make sure the product’s means 

9. 

of grounding or polarization is not defeated.
Power  cord  protection.  Power  supply  cords  should 

10. 

be  routed  so  that  they  are  not  likely  to  be  walked  on  or 
pinched  by  items  placed  upon  or  against  them,  paying 
particular attention to cords at plugs, receptacles, and the 
point where they exit from the appliance.
Non-use Periods. The power cord of the appliance should 

11. 

be unplugged from the outlet when left unused for a long 

SAFETY INSTRUCTIONS

period of time. To remove all power (supply mains) from the 
appliance, remove the plug from the wall outlet and remove 
batteries from the handset.
Keep product clean. From time to time, wipe off the product 

12. 

with  a  clean  soft  cloth.  Don’t  use  abrasive  materials, 
thinners, alcohol, or chemical solvents.
Avoid  spills  and  foreign  objects.  Make  sure  liquids  and 

13. 

objects don’t get into the product enclosure through any 
openings.
Get  professional  service.  Have  the  product  serviced 

14. 

only  by  qualified  service  personnel  when:  a)  The  power 
supply  cord  or  the  plug  has  been  damaged;  b)  Liquids 
have  spilled  or  objects  have  fallen  into  the  product;  
c) The product has been exposed to rain; d) The product 
doesn’t operate normally or is damaged

Don’t attempt to service the product yourself. Doing so will void 

the warranty. 

If you have any questions, call Russound at 1.800.638.8055 

or 603.659.5170.

Compliance Statement (Part 15.19):

This hardware device complies with Part 15 of the FCC 

Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) 
This device must accept any interference received, including 
interference that may cause undesired operation. 

Warning (Part 15.21):

Changes  or  modifications  not  expressly  approved  by 

the  party  responsible  for  compliance  could  void  the  user’s 
authority to operate the equipment.

FCC Interference Statement (Part 15.105 (b)):

This  equipment  has  been  tested  and  found  to  comply 

with the limits for a Class B digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide 
reasonable  protection  against  harmful  interference  in  a 
residential installation. This equipment generates, uses, and 
can  radiate  radio  frequency  energy  and,  if  not  installed  or 
used in accordance with the instructions, may cause harmful 
interference  to  radio  communications.  However,  there  is 
no  guarantee  that  interference  will  not  occur  in  a  particular 
installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following 
measures:  1)  reorient  or  relocate  the  receiving  antenna;  2) 
increase  the  separation  between  the  equipment  and  the 
receiver; 3) connect the equipment to an outlet on a circuit 
different  from  that  to  which  the  receiver  is  connected;      

4) consult the dealer or an experienced radio/TV technician 
for help. 

Section 7.1.5 of RSS-GE

N

:

Operation  is  subject  to  the  following  two  conditions:  (1) 

This device may not cause harmful interference, and (2) This 
device  must  accept  any  interference  received,  including 
interference  that  may  cause  undesired  operation  of  the 
device. 

RF Exposure Compliance - Cradle Charger

To  comply  with  FCC  and  Industry  Canada  RF  exposure 

limits  for  general  population/uncontrolled  exposure,  the 
charging  cradle  must  be  installed  to  provide  a  separation 
distance of at least 7.9 in (20 cm) from all persons and must 
not be co-located or operating in conjunction with any other 
antenna or transmitter. 
R

F Exposure Compliance - RF Handset 

(Handheld Remote)

To  comply  with  FCC  and  Industry  Canada  RF  exposure 

limits  for  general  population/uncontrolled  exposure,  the 
handheld  remote  must  be  operated  only  in  the  hand  to 
provide a separation distance of at least 7.9 in (20 cm) from 
the body (excluding the hand and the wrist) and must not be 
co-located or operating in conjunction with any other antenna 
or transmitter. 

Battery Use and Disposal Instructions:

CAUTION: the battery in used in this device may present a 

risk of fire or chemical burn if mistreated. Do not disassemble, 
expose the to heat above 70 degrees C (158 degrees F) , 
incinerate,  or  immerse  in  water  or  liquid  of  any  kind.  Do 
not  use  or  charge  the  battery  if  it  appears  to  be  leaking, 
discolored, deformed, or in any way abnormal. Do not leave 
your  battery  discharged  or  unused  for  extended  periods  of 
time.  When  the  battery  is  misused,  it  may  explode  or  leak, 
causing  burns  or  other  personal  injury.  If  the  battery  leaks, 
use  normal  precaution  and  discard  it  immediately  following 
the laws and regulations governing battery disposal in your 
area. Remember that a leaking battery can caused skin burns 
or other personal injury. Keep this an all batteries out of the 
reach of children. Risk of explosion if battery is replaced with 
an incorrect battery type.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC 
SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR 
MOISTURE

.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE THE COVER. NO USER-SERVICEABLE 
PARTS  INSIDE.  REFER  SERVICING  TO  QUALIFIED 
SERVICE PERSONNEL.

Содержание RFR-E5

Страница 1: ...RF Remote Control RFR E5 Premier products for Russound Sphere Certified Professionals E Series Installation Manual ...

Страница 2: ...erence and 2 This device must accept any interference received including interference that may cause undesired operation Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Interference Statement Part 15 105 b This equipment has been tested and found to comply with the limits for a C...

Страница 3: ...connection 8 System binding zone setup 9 How to choose a source 10 How to make room audio adjustments 11 Set clock 12 Installation menu 13 Local source setup and IR control 14 Learn IR for local sources 15 Diagnostics 16 Authorize support factory initialization 17 Update firmware 18 IR device codes 19 21 Technical specifications 22 Warranty 23 ...

Страница 4: ...cate over LAN with the controller Besides its wide range wireless operation via RF one of the RFR E5 s main features is its ability to roam to and control other zones It offers the same level of source selection and control as the KLK E5 keypad and enjoys the same touch ring technology to easily scroll through menus and long lists of channels presets artist names and song titles The RFR E5 display...

Страница 5: ...te and make selections using marked push buttons on the wheel Menu Go to top level option screen for current source Transport standard controls for navigation and source commands Talk back LED Red LED indicates IR use Select Press to activate a selected item from a menu Also press for easy source selection from the Now Playing screen brings up source list Number Pad Digits 0 9 for numeric entry of...

Страница 6: ...e controller over a 10 100 1000 1Gigabit recommended Base T Ethernet network via the CAT 5 RJ45 connector on the rear of the cradle The cradle is powered by a detachable power supply that plugs into the rear of the cradle The cradle provides the remote with the appropriate DC voltage for battery charging through two contacts when docked in the cradle Cradle back view Remote control and cradle Crad...

Страница 7: ... the battery icon Battery Use and Disposal Instructions CAUTION Danger of explosion if the batteries are improperly replaced Replace ONLY with the same type Russound P N E150 531217 Batteries are to be serviced by the installer only This device contains a replaceable lithium ion rechargeable battery Battery life is dependent upon usage Heavy daily use will result in shorter battery life Casual use...

Страница 8: ...it recommended or router The ACA E5 and RFR E5 s must be on the same subnet LAN WAN Required DHCP router with NAT firewall CAT 5 cable CAT 5 cable max 250 feet from controller to cradle CAT 5 cable CAT 5 cable ACA E5 controller Cradle RJ45 wall plates Ethernet connection Cable or DSL Modem INTERNET cradle controller connection Connect the power supply to the cradle Connect the cradle to the LAN po...

Страница 9: ...e remote to the cradle The RFR ID screen appears within Installation menu This screen lets you set the unique ID number for an RFR when multiple RFR E5s are in a system The default is ID 1 to make installation of a single RFR E5 easy The RFR ID does not have to match the zone number but each RFR must have a unique number assigned The remote screen moves to the Default Zone menu within Installation...

Страница 10: ...ts All music video sources audio adjustments and system settings are arranged in menus and lists Choose music or video source From the home screen scroll to and select Sources A list of available sources appears Scroll to and select a source Also press Select while on a source s Now Playing screen Play music or video Once you have chosen a source you can select music or a video to play from that s...

Страница 11: ... to and select Settings and choose Audio Settings You ll see items to adjust such as bass treble and balance Each selection has its own screen and shows levels for real time adjustments For volume adjustments press the Volume up down buttons on the remote To mute the room s audio press the Mute button ...

Страница 12: ...umbers Press next and previous on the wheel to move the cursor and press select to save Set Date From the Clock menu select Set Date The date format is month day year Scroll with the touch wheel or press the wheel s and to move through numbers Press next and previous on the wheel to move the cursor and press select to save Clock Format There are two clock formats to choose from From the home menu ...

Страница 13: ... Provides the installer with a variety of display and button operation tests to diagnose unplanned behaviors Authorize Support This option enables the system to be accessed remotely so the dealer or Russound tech support can access the system over Ethernet for diagnostics update or programming Default Zone Allows the installer to choose from a list of all zones the default zone to which the RFR E5...

Страница 14: ... On the source setup screen scroll to the appropriate device type and press the Select button The type selected will populate the Type box Choose the appropriate 4 digit device code from the list in the back of this manual and enter it in the code box using the numeric buttons on the RFR E5 Press the Select button to enter Local Source IR Control To operate a local source with the RFR E5 point the...

Страница 15: ... remote Under Choose Device Type scroll to Learned IR and press the select button Press key on RFR E5 where you want to learn the command The display will show the key name The red talk back LED at the top of the RFR E5 will blink when it is ready to accept commands from the donor remote Point the source donor remote at IR window at the top of the RFR E5 Press and hold the key on donor remote to l...

Страница 16: ...me If the button is functioning properly the name of the button appears on the screen Zone controls are deactivated during the button test no controller response should occur The backlight remains on during the test so the screen can be read Press and hold Power to exit the test Display Test This selection tests the RFR E5 s display window Choosing all on activates all the screen s pixels appears ...

Страница 17: ... number will be provided in the Session Number box A Press Menu for Details message is displayed if there is a problem establishing a tunnel During the support tunnel process the system is unavailable for use Factory Initialization If it becomes necessary the RFR E5 s settings can be returned to factory state through a factory initialization from the RFR E5 A factory initialization deletes all pro...

Страница 18: ...update port is located on the back of the remote behind the battery access door The cradle update port is located on the bottom of the unit behind a small removable panel For both pieces the Russound USB A4P USB Programming Cable Russound P N 8300 531415 is used to connect the port to a PC for the update procedure Update port on bottom of cradle with access door removed Update port on remote contr...

Страница 19: ...Portland 0092 Prima 0761 Princeton 0700 Prism 0051 Proscan 1447 0047 1347 1922 Proton 0178 Pulsar 0017 Quasar 0250 0051 Radio Shack 0047 0154 0180 0030 0178 1904 RCA 1447 0047 1047 1347 1917 0679 1247 1547 1948 0090 1147 1922 Realistic 0154 0180 0030 0178 Runco 0017 0030 Sampo 0030 1755 Samsung 0060 0812 0702 0030 0178 0766 1959 1060 Sansui 0463 1935 1911 1904 Sanyo 0154 0088 Scotch 0178 Scott 023...

Страница 20: ...1972 HI Q 0047 Hitachi 0000 0042 0041 0089 Howard Computers 1972 Hughes Net Sys 0042 0739 iBUYPOWER 1972 Jensen 0041 JVC 0067 0041 KEC 0037 0278 Kenwood 0067 0041 0038 KLH 0072 Kodak 0035 0037 Lloyd s 0000 Logik 0072 LXI 0037 Magnavox 0035 0039 0081 0000 0149 Magnin 0240 Marantz 0035 0081 Marta 0037 Matsushita 0035 0162 Media Center PC1972 MEI 0035 Memorex 0035 0162 0037 0048 0039 0047 0240 0000 0...

Страница 21: ...189 1269 0189 Pioneer 1023 0150 0014 0630 0531 Polk Audio 0189 Proscan 1254 Quasar 0039 RadioShack 1263 RCA 1023 1609 1254 1074 0531 Rio 1383 Sansui 0189 Sharper Image 1263 Sonic Blue 1383 Sony 1058 1759 0158 1406 Soundesign 0670 Stereophonics 1023 Sunfire 1313 Teac 1074 Technics 1308 0039 0309 Thorens 1189 Victor 0074 Wards 0158 0189 0014 Yamaha 0176 1276 1176 Device Codes for Amp and Misc Audio ...

Страница 22: ...t indoor 325 feet outdoor typically depends on conditions Battery 3 7V 800 mAh Lithium ion cell qty 2 Battery life 36 hours in standby 11 hours active Actual battery life dependent upon use Cradle for Remote Control Dimensions 3 0 W x 2 37 H x 7 11 D 78 5 x 60 x 180 mm Weight 1 lbs 0 45 kg Power 5 VDC 1A Power supply 100 240V 50 60 Hz 300mA Network connection RJ45 T568A standard connector Programm...

Страница 23: ...rect any defect in workmanship without charge for either parts or labor For this warranty to apply the unit must be installed and serviced by a Russound Sphere Certified Integrator and used in accordance with written instructions If service becomes necessary please contact your local Russound Sphere Certified Integrator to arrange for product return This Warranty does not cover Damage caused by ab...

Страница 24: ...l trademarks are the property of their respective owners Specifications are subject to change without notice Russound is not responsible for typographical errors or omissions 28 1299 02 18 09 Russound Inc 5 Forbes Road Newmarket NH 03857 tel 866 604 5245 fax 603 292 8352 www russoundsphere com E Series Installation Manual ...