Symptom
Potential cause
Remedies
Fixture does not
respond to DMX
control.
Fault in the DMX
network due to
connector or cable
damaged, or
incorrect DMX
addressing, or
potential interference
from proximity to a high
voltage installation.
Check that the fixture DMX
LED is on, and if not, check
all DMX cables and
connections to ensure the
integrity of the physical
network.
Ensure that the DMX
network is terminated.
Check that the components
in the DMX network all use
standard DMX polarity.
Ensure that the fixture is
set to the correct DMX
address, one that matches
that set on the DMX control
device.
Check the pins on the
connectors from the
previous fixture in the DMX
network.
Attempt to control the
fixture with another DMX
control device.
Move the fixture if it is
being operated very close
to an unshielded high-
voltage installation.