AC power
Read Safety information on page 5 before connecting the fixture
to AC mains power.
For protection from electric shock, the fixture must be grounded
(earthed). The power distribution circuit must be equipped with a
fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixtures can easily be disconnected from
power.
Do not insert or remove live Neutrik PowerCon connectors to
apply or cut power, as this may cause arcing at the terminals
that will damage the connectors.
Do not use an external dimming system to supply power to the
fixture, as this may cause damage to the fixture that is not
covered by the product warranty.
Use only Neutrik PowerCon cable connectors to connect to power sockets.
Power input and throughput cables must be rated 20 A minimum, have three
conductors 1.5 mm² (16 AWG) minimum conductor size and an outer cable
diameter of 5 - 15 mm (0.2 - 0.6 in.). Cables must be hard usage type (SJT or
equivalent) and heat-resistant to 90° C (194° F) minimum. In the EU the cable
must be HAR approved or equivalent.
Cables used for power throughput must meet the same specifications as for
power input cables.
The fixture can be hard-wired to a building electrical installation if you want to
install it permanently, or a power plug that is suitable for the local power outlets
can be installed on the power cable.
The fixture has an auto-ranging power supply that accepts AC mains power at
100V~240V, 50/60Hz. Do not apply AC mains power to the fixture at any other
voltage than this.