Chapter 1 Product Overview
Installation Manual
1-24
Indicator
Description
Link
Solid on means the physical connection is set up.
OFF means the physical connection is unsuccessfully
RDY
On means the sub-card initialization after power on is done.
Off means the sub-card initialization after power on is
unsuccessful.
1.3.1.2
Module Attributes
HS is the abbrevation of the synchronous serial port.The basic features are as follows:
SIC-1HS indexes
Protocol
Supporting V.24/V.35, with automatic cable identification
Rate
The sync port of a single-sync card supports 9600-8.192M bps.
LED
Two
One port LINK status LED, which turns on when the connection
to the physical link is set up and the upper layer protocol is up
One link card RDY status LED indicator, which turns on when
the motherboard detects the line card
Interface DB26
Environment
Operating temperature: 0
℃~
45
℃
;
Operating humidity: 10
%~
90
%
;
Storage temperature: –40
℃~
70
℃
EMC
EMI: GB 9254-1998 Class A
EMS: GB/T 17618-1998
1.3.1.3
Module Cable
The following cables can be used:
V.24
DTE
V.24
DCE
V.35
DTE
V.35
DCE
V.35 DTE-V.35 DCE
The figures of these cables are as below:
V.24
DTE