Hardware Installation and Reference Guide
Overview
11
LED
Panel Identification
Status
Meaning
personnel to perform remote power on and off
control.
Solid green
The switch is operational.
Solid yellow
Temperature alarm:
1. The temperature of inlet/outlet vent exceeds
the warning threshold.
2. The power is insufficient for the system .
Check the working environment of the switch
and power supplies immediately.
Solid red
1. The temperature of the inlet/outlet vent
exceeds the warning threshold.
2. The switch is faulty.
Power supply status
LED
PWR1/PWR2
Off
The power supply module is not in place or not
powered on.
Solid green
The power supply module is operating
normally.
Solid red
The redundant power is faulty or the AC power
cord is not connected.
MGMT port status
LED
MGMT
Off
The port is not connected.
Solid green
The port is connected at 1000 Mbps .
Blinking green
The port is receiving or transmitting data at
1000 Mbps.
Solid yellow
The port is connected at 10/100 Mbps.
Blinking yellow
The port is receiving or transmitting data at
10/100 Mbps.
10GE SFP+ port
status LED
49F-52F
Off
The port is not connected.
Solid green
The port is connected at 1/10 Gbps.
Blinking green
The port is receiving or transmitting data at
1/10 Gbps.
10/100/1000Base-T
Ethernet port status
LED
1-48
Off
The port is not connected.
Solid green
The port is connected at 1000 Mbps .
Blinking green
The port is receiving or transmitting data at
1000 Mbps.
Solid yellow
The port is connected at 10/100 Mbps.
Blinking yellow
The port is receiving or transmitting data at
10/100 Mbps.
1.4 RG-S5760C-24SFP/8GT8XS-X
Technical Specifications