Hardware Installation and Reference Guide
Overview
15
The
S5760C-24SFP/8GT8XS-X
supports two power supply modules. Dual-power input: The switch can be powered by
one power supply module, or two power supply modules. When both two modules are working, the switch is working in
power redundancy mode.
Heat Dissipation
The RG-
S5760C-24SFP/8GT8XS-X
uses left-to-right airflow for heat dissipation, thereby ensuring the normal function of
the device in the specified environment. Maintain a minimum clearance of 10 cm (3.94 in.) around the chassis to allow air
circulation.
Figure 1-12 Flow Scheme of Heat Dissipation
LED
LED
Panel Identification
Status
Meaning
System LED
Status
Off
The switch is not powered on.
Blinking green
(3 Hz)
Initialization is in progress. Continuous blinking
indicates a fault.
Blinking green (10
Hz)
It is used for on-site positioning of the device,
and allows operation and maintenance
personnel to perform remote power on and off
control.
Solid green
The switch is operational.
Solid yellow
Temperature alarm:
1. The temperature of inlet/outlet vent exceeds
the warning threshold.
2. The power is insufficient for the system.
Check the working environment of the switch
and power supplies immediately.
Solid red
The switch is faulty. For details, see
Troub leshooting
.