Hardware Installation and Reference Guide
Installing the Switch
28
3.3 Mounting the Switch
Precautions
During installation, note the following points:
Connect the power cables of different colors to the corresponding grounding connectors.
Ensure that the power cables are well grounded.
Do not place heavy objects on the switch.
Maintain a minimum clearance of 10 cm (3.94 in.) around the chassis to facilitate heat dissipation. Do not stack the
devices.
Keep the switch far away from high-frequency current devices such as high-power radio transmitting station and radar
launcher. Take electromagnetic shielding measures when necessary, such as electromagnetic shielding cables.
Adopt indoor cabling. Outdoor cabling is prohibited to prevent damages to interfaces due to over-voltage or over-
current caused by lightning.
3.3.1 Mounting the Switch into a Cabinet
The RG-S5760C-X series switches follow the EIA standard dimensions and can be installed in 19-inch cabinet. During
the installation, place the front panel on the front part of the bracket. For safety, fasten screws to secure the bracket on
the switch, as shown in the 3-1.
Figure 3-1 Securing the Mounting Bracket on the Switch