Hardware Installation and Reference Guide
Overview
10
Note:
1. Grounding Lug
2. Filler Panel
3. Filler Panel (Non-expansion Module)
4. Power Supply Module Slot 1
5. Power Supply Module Slot 1
Power Supply
The RG-S5760C-48GT4XS-X supports two power supply modules. Dual-power input: The switch can be powered by one
power supply module, or two power supply modules. When both modules are working, the switch is working in power
redundancy mode.
Heat Dissipation
RG-
S5760C-48GT4XS-X
uses left-to-right airflow for heat dissipation, thereby ensuring the normal function of the device
in the specified environment. Maintain a minimum clearance of 10 cm (3.94 in.) around the chassis to allow air
circulation.
Figure 1-8 Flow Scheme of Heat Dissipation
LED
LED
Panel Identification
Status
Meaning
System LED
Status
Off
The switch is not powered on.
Blinking green
(3 Hz)
Initialization is in progress. Continuous blinking
indicates a fault.
Blinking green
(10Hz)
It is used for on-site positioning of the device,
and allows operation and maintenance