Hardware Installation and Reference Guide
Monitoring and Maintenance
36
5 Monitoring and Maintenance
5.1 Monitoring
Indicator
When the RG-S5760C-X switch is running, you can monitor the module status by observing the module indicator
If the SYS indicator of the device is red, it indicates that the power supply module is faulty or not in place or the service
module is faulty. Log in to the web-based management system to confirm and troubleshoot the fault.
If the SYS indicator of the device is yellow, it indicates that the system temperature reaches the warning value or the
service module is abnormal. This case may affect the system performance, but the system can keep running. Log in
to the web-based management system to confirm and troubleshoot the fault.
If the SYS indicator of the device is red, it indicates that the module is faulty. Check the cause of the fault. Cut off the
power supply if necessary.
When the PWR1/PWR2 indicator of the device is yellow, it indicates that the power is not sufficient to support the
whole system, insert RPS modules.
When the PWR1/PWR2 indicator of the device is red, check whether the power cord is in place and operational; if
yes, it indicates that the power supply is faulty, replace the power supply in time.
The fast flashing green (10 Hz) status of the system indicator is a function used to locate the switch, which should
be distinguished from the slow flashing status (3 Hz).
CLI Commands
The switch allows you to monitor various system statuses by executing the appropriate CLI commands, including:
Working status of the switch
Configuration information and status of port
Working status of fan and power supply
Temperature status
For the monitoring commands, refer to
RG-S5760C-X Series Switch RGOS Configuration Guide
.
5.2 Maintenance
Ventilation System M aintenance
The fan module responsible for heat dissipation is equipped with the fault monitoring signal. When the fan module is
faulty, an alarm will occur.
Power off the device, and replace the faulty fan module with a qualified one.
Power Supply M odule Maintenance
When a power supply module is faulty, unplug the power cord, press the latch, grab the handle, pull it out, replace it with
a qualified one, and then plug the power cord.