2)
Levelly lift the RG-S12000 to a position slightly higher than the tray or the slide rail of the cabinet, put the equipment
onto the tray or the slide rail, and push it into the cabinet.
3)
Fasten the RG-S12000 onto the cabinet with screws. There are fastening notches on both the sides of the front
panel on the equipment frame. Use screws to fasten them to the fastening bracket of the cabinet. After fastened, the
equipment should be stable and still in the cabinet.
Installing and Removing Fan Tray
The RG-S12000 provides a ventilation system: M12006-FAN I for RG-S12006, M12010-FAN I for RG-S12010. Before the
following procedures, wear an anti-static wrist trap close to your skin and have it properly grounded.
Steps for installing the M12006-FAN I fan tray:
1)
Install the fan tray into the fan slot in the back panel of RG-S12006. Note the direction identifier of the fan tray’s name
to ensure the correct direction.
2)
Tighten the captive screws on the fan tray with a screwdriver.
Steps for installing the M12010-FAN I fan tray:
1)
Install the fan tray into the RG-S12010 along the guide rail in the front panel. Note the direction identifier of the fan
tray’s name to ensure the correct direction.
2)
Slide the fan tray into position gently with both hands.
Steps for removing the M12006-FAN I fan tray:
1)
Loosen the captive screws on the fan tray with a screwdriver.
2)
Grasp the two handles on the fan tray and gently remove the fan tray.
Steps for removing the M12010-FAN I fan tray:
Press the “Push” location of the two handles with both hands to unfold the handles, and grasp the unfolded handles to pull
the fan tray out.
Do not remove the M12010-FAN I fan tray forcibly, use the fan handle. Otherwise, component damage may
occur, which causes deformation of the fan tray, and the fan tray cannot be removed.
Installing and Removing the Dust Cap
Plastic dust caps for the system switching power supply module, host management module, and service module on the
RG-S12000 need to be configured.
If a dust cap is used for a long time, dust in the air may block its air vent, weakening system ventilation. It is
recommended you wash dust caps every three months.
Installing and Removing the Air Filter of a System Switching Power Supply
Figure 3-2 Location for installing the air filter of the RG-PA1200I/RG-PA2000I