Graphical User Interface
QoS
Create / Modify Meter
QoS > Policy Config > Create / Modify Meter
The Create / Modify Meter menu item sets and displays meter actions.
Create Meter
■
ID:
Sets the meter ID. May be 1 to 65535.
■
Rate:
Sets the meter rate. May be 64 to 1048512.
■
Bucket Size:
Sets the bucket size. Default 4K.