Digital output port
The ECR60/ECT60 contains two photoelectric isolation output signals.
OUT1 has an output current capacity of 30mA.
OUT2 has an output current capacity of 150mA.
The digital output port is all normally open by default, the function of the output port
can be selected by object dictionary 2005, and the object dictionary 2006 is used to set
the polarity of the set output port.
Object
dictionary
Name
Proper
ty
Type
Range
The
default
value
Unit
Note
0x2005:01 Output Port
1 Function
R/W/S UINT
0 to 3
1
---
Output port feature
selection:
0 - Custom output
1 - Alarm output
2 - Holding gate
output
3 - Output in place
0x2005:02 Output port
2 function
R/W/S UINT
0 to 3
2
---
0x2006
Output port
polarity
settings
R/W/S UINT
0 to 3
3
---
Set the normally open,
normally closed
feature of the output
port
0 - Often closed
1 - Always open
Содержание ECT60
Страница 11: ...ECR60 ECT60 User manual 10 DC12 24V DC12 24V OUT1 DG DC12 24V OUT1 DG...
Страница 15: ...ECR60 ECT60 User manual 14 1 7 Mechanical size...
Страница 21: ...ECR60 ECT60 User manual 20...
Страница 27: ...ECR60 ECT60 User manual 26...
Страница 58: ...ECR60 ECT60 User manual 57 Probe Time Series...
Страница 64: ...ECR60 ECT60 User manual 63 2 4 6 4 Method 19 2 4 6 5 Method 20 2 4 6 6 Method 21...
Страница 65: ...ECR60 ECT60 User manual 64 2 4 6 7 Method 22 2 4 6 8 Method 23...
Страница 66: ...ECR60 ECT60 User manual 65 2 4 6 9 Method 24 2 4 6 10 Method 25...
Страница 67: ...ECR60 ECT60 User manual 66 2 4 6 11 Method 26 2 4 6 12 Method 27...
Страница 68: ...ECR60 ECT60 User manual 67 2 4 6 13 Method 28 2 4 6 14 Method 29...
Страница 69: ...ECR60 ECT60 User manual 68 2 4 6 15 Method 30 2 4 6 16 Method 35...
Страница 71: ...ECR60 ECT60 User manual 70...