ECR60/ECT60 User manual
60
Back to zero mode
Set back to zero parameters
Set back to zero speed, acceleration, zero offset and related sensor input signal.
The relevant object dictionary is as follows:
Object
dictionary
Description
0x607C
Zero offset
0x6098
Zero-back method setting
0x6099
Zero-back speed
0x609A
Back zero and deceleration
0x2007
Input port feature selection
0x2008
Enter port polarity settings
Enable zero function:
To be able to track position mode, the value of the object dictionary 6060h (operating
mode) must be set to 0006h. The object dictionary 6061h (operation mode display) can
be used to confirm that the drive is in the correct operating mode.
After the drive is initially powered on, it is in a non-enabled state. Write to the control
word 6040h 6, set the drive to the"ready to switch on"state, then write 000Fh to the
control word 6040h, set the drive to "Operation Mode Mode".
Start back to zero:
The back zero method is set up through the 6098h object dictionary.
Содержание ECT60
Страница 11: ...ECR60 ECT60 User manual 10 DC12 24V DC12 24V OUT1 DG DC12 24V OUT1 DG...
Страница 15: ...ECR60 ECT60 User manual 14 1 7 Mechanical size...
Страница 21: ...ECR60 ECT60 User manual 20...
Страница 27: ...ECR60 ECT60 User manual 26...
Страница 58: ...ECR60 ECT60 User manual 57 Probe Time Series...
Страница 64: ...ECR60 ECT60 User manual 63 2 4 6 4 Method 19 2 4 6 5 Method 20 2 4 6 6 Method 21...
Страница 65: ...ECR60 ECT60 User manual 64 2 4 6 7 Method 22 2 4 6 8 Method 23...
Страница 66: ...ECR60 ECT60 User manual 65 2 4 6 9 Method 24 2 4 6 10 Method 25...
Страница 67: ...ECR60 ECT60 User manual 66 2 4 6 11 Method 26 2 4 6 12 Method 27...
Страница 68: ...ECR60 ECT60 User manual 67 2 4 6 13 Method 28 2 4 6 14 Method 29...
Страница 69: ...ECR60 ECT60 User manual 68 2 4 6 15 Method 30 2 4 6 16 Method 35...
Страница 71: ...ECR60 ECT60 User manual 70...