OPERATION & MAINTENANCE MANUAL

 

CompactFreezer

 

 

26 

 

15.

 

Check the temperature and condition of the food coming out of the freezer. Make one or more 
of the following adjustments if required: 

a.

 

belt speed and/or belt loading 

b.

 

production rate 

c.

 

set point temperature  

 

7.3.

 

PRODUCTION INTERRUPTIONS

 

 

Shutdown  of  the  freezer  for  relatively  short  production  interruptions  such  as  breaks,  lunch  period  or 
production breakdown, a procedure that fits the processing line operation method should be established 
and adhered to. 

 

A.

 

If the production crew at the discharge end of the freezer remains to run out and pack 
off the  product, the  temporary shutdowns  would be  to turn off  the instrument power 
when the freezer is emptied of product. Let the conveyor belt and fans run for production 
interruptions of 30 minutes or less. 

 

B.

 

If, for some reason, the packing crew at the discharge end of the freezer leave the line 
at  the  same  time as  the crew  at  the  infeed  end  of  the  freezer;  it  would  usually  mean 
that there will be product running through the freezer on the conveyor. In this case, the 
temporary shutdown would be to turn off instrument power, the fans, and the conveyor. 

 

C.

 

Three or four minutes before restarting production, start the fan motors and  conveyors, 
checking to  make  sure everything is  working,  then  push the  instrument power  to cool 
the  freezer  to  desired  temperature.  The  product  left  is  in  the  freezer  over  the  shut 

down may be over‐frozen by being left in the cold

 atmosphere. 

 

 
 
 
 

7.4.

 

VAPOR EXHAUST COLLECTION AND DISCHARGE

 

 

There is a vapor collection trough at each end of the freezer. The vapor exhaust blowers suck the vapors 
to the outside of the building. 

 

Blast  Gate  Damper 

  A  blast  gate  damper  installed  in  the  ductwork  near  the  duct  connection  to  the 

freezer  controls  the  suction  draw  from  the  exhaust  blower.  For  best  efficiency,  this  should  be  to  the 
point where the vapor flow almost spills over into the room.  Adjustments should be made throughout 
the day. 

 
 

7.5.

 

PRODUCT TEMPERATURE EQUILIBRATION

 

 

Equilibration is the process of equalizing the temperature of the center and outside of the product. This 
occurs with time; the amount of time depending on the thickness of the product. 

 

When a product is frozen in a cryogenic freezer, a frozen crust will quickly form on the outside surface, 

Содержание COMPACT FREEZE TUNNEL

Страница 1: ...tenance Manual COMPACT FREEZE TUNNEL Liquid Nitrogen Cryogenic Freezer For service or support please call RS CRYO EQUIPMENT INC 629 Grove Street Manteno IL 60950 Phone 815 468 6115 Fax 815 468 2651 ht...

Страница 2: ...1 3 8 Temperature Control System 11 4 Installation Assembly 12 4 1 Site SelectionRequirements 12 4 2 Unloading the Compact Freezer 13 4 3 Positioning the Freezer 13 4 4 Connecting Freezer Sections and...

Страница 3: ...9 3 Conveyor and Conveyor Drive 35 9 4 Safety Relief Valves 36 9 5 Module Joints 36 9 6 Solenoid Valves 36 9 7 Strainer 36 9 8 Doors 36 9 9 Headers and Orifices 37 9 10 Temperature Controller 38 9 11...

Страница 4: ...re that all separately packed items exhaust spare parts bolts etc have beenreceived If there is any damage all claims must be made promptly to the shipping company The RS Cryo Equipment representative...

Страница 5: ...llows humid air into the freezer and may cause the system to freeze up Never reach inside the freezer when it is running Doing so may result in bodily injury from cold burns Never leave the freezer un...

Страница 6: ...o ensure the proper removal of nitrogen vapor To re start freezer turn the fan conveyor and instrument power buttons to the off position Once all three are OFF then turn each back to the on position F...

Страница 7: ...to increase Unless this pressure can bleed back into the supply tank or out a safety relief valve it may burst the line Safety relief valves should be piped to an outside area Always open valves slow...

Страница 8: ...OPERATION MAINTENANCE MANUAL CompactFreezer 7 3 About the Compact Freezer 3 1 EQUIPMENT SPECIFICATIONS COMPACT FREEZER FREEZER MODULES LENGTH 1 83 2 122 3 161 38 38 7 40 48 120V SINGLE PHASE 35AMP...

Страница 9: ...duct heat load If the product flow stops the freezer automatically reduces the liquid nitrogen injection rate to the minimum required to maintain the freezer operating set point temperature A key erro...

Страница 10: ...OPERATION MAINTENANCE MANUAL CompactFreezer 9 warm outer surfaces of the parts to keep cooling losses to a minimum All fasteners...

Страница 11: ...erials approved by inspection agencies for use as food contact surfaces The upper and lower doors open on each side of the freezer to fully expose the inside for ease of cleaning 3 4 CONVEYOR S BELT S...

Страница 12: ...n motor push button station 1 per freezer for variable speedfans 2 Conveyor drive push button station 1 per drive 3 Instrument power push button station 4 Exhaust blowers push button station 5 Tempera...

Страница 13: ...hat require the use of extension headers have piping run to either the preceding or following module with a duplicate header system in those modules For optimal freezing capacity the Compact Freezer t...

Страница 14: ...fully map out the path to the installation area prior to unloading the Compact Freezer from the truck Determine the most suitable freezer orientation to pass through all bottle necks and to assure cor...

Страница 15: ...r must be unloaded by means of a crane or forklift The recommended means of transport is on industrial rollers if a crane or forklift can not be used Ensure that the total weight of the freezer does n...

Страница 16: ...end only The first module of the second crate should be positioned to extend about 2 onto the exposed pedestal half mounting surface F Uncrate the modules G Coat to inner mating surface of modules wi...

Страница 17: ...drive sprockets teeth areengaged Install scraper belt at exit end of top belt and adjust it just short of touching the bet Do the same for exit chute on bottom belt 4 6 LEVELING THE FREEZER The freeze...

Страница 18: ...e installation drawing for each blower mounting is forwarded to the customer to pass on to his installation contractor who is normally responsible for mounting and connecting the exhaust to the trough...

Страница 19: ...cation of the controller and shielded wire should be as remote as possible relative to any AFC generating unit controller to prevent pick up of RF noise Six inches is tooclose 1 Earth Ground Earth gro...

Страница 20: ...source of liquid nitrogen from a storage tank The liquid nitrogen supply piping connects the storage tank with the liquid nitrogen injection system of the freezer Insulate all liquid nitrogen piping u...

Страница 21: ...his will allow for proper exhaust system performance and reduce negative pressure in the production area Protect the exit of the exhaust system against bad weather conditions and or birds Minimize the...

Страница 22: ...ezer Room air can bring moisture into the freezer therefore affecting the efficiency and economical operation of the freezer 6 Initial Start up and Tuning The Cabinet Freezer was factory tested before...

Страница 23: ...control panel are OFF 9 With the main disconnect in the OFF position use a multi meter to check that the proper voltages and amperage is supplied to the control panel 10 Open the main shut off valve a...

Страница 24: ...nveyor at approximately a 45 angle 6 3 OPERATING TEMPERATURE The normal operating temperature of the Cabinet Freezer tunnel can be adjusted from 50 F to 125 F 10 C to 120 5 C for most products for opt...

Страница 25: ...slowest speed that will handle the required production and then increase the freezer operating temperature to the warmest temperature that will produce the desired results This is the most economical...

Страница 26: ...e running daily 2 Check solenoid valve operation at least weekly 3 Check conveyor belt slack frequently 4 Change conveyor drive gear box oil as specified in component manual 7 2 DAILY START UP AND OPE...

Страница 27: ...king the residence time The speed of the in feed and discharge conveyors should be matched to assure a smooth product transfer 10 Check that the liquid nitrogen is injecting into the freezer This star...

Страница 28: ...he conveyor In this case the temporary shutdown would be to turn off instrument power the fans and the conveyor C Three or four minutes before restarting production start the fan motors and conveyors...

Страница 29: ...e frozen shell Equilibration occurs in the package where the refrigeration of all pieces compliments eachother 7 6 SHUTDOWN At the end of a production shift the freezer should be shut down in the foll...

Страница 30: ...rotect electrical components from water moisture damage with plastic bags if possible Wear gloves and safety glasses to avoid personal injury from high pressure hot water or steam jets Remove or secur...

Страница 31: ...freezer as dry as possible It is recommended that with all power off both the upper and lower doors be left open until the next productionshift 10 Any removable parts that were taken off the freezer...

Страница 32: ...l accessory not included with allunits 9 2 CONVEYOR AND CONVEYOR DRIVE Conveyor Belt Inspect the belt daily for the first several days of operations and semi monthly afterwards A tensioning device is...

Страница 33: ...conditions Conveyor Drive Gear Reducer Change oil after every 1 000 hours of operation Use Mobil 600W cylinder oil or equivalent 9 3 SAFETY RELIEF VALVES Safety Relief Valves should be located between...

Страница 34: ...hold down strip and screws Do not force the screwstight Door Safety Switch The adjustment of the door safety switch actuation is done in the followingsequence 1 Make sure power is turned OFF 2 Loosen...

Страница 35: ...tion The lower limit set point is programmed to not exceed 125 F 130 C but can be reprogrammed for warmer or colder limits if the situation warrants it Control functions alarm settings and other param...

Страница 36: ...rom inside the apparatus box and free the cable 2 Remove fan blade by first loosening the two cross bolts on it Remove hex cap screw and thrust washer and slide fan blade and key off the shaft 3 Remov...

Страница 37: ...z electrical power supply Use the electrical schematic in Appendix B Reference Drawings for more information with respect to the voltage requirements and other specifications The variation in supply v...

Страница 38: ...order Check if the emergency stops have been activated Reset if necessary Check if the main fuses of the drive motor belt are intact If the conveyor belt does not run at a smooth uniform speed check...

Страница 39: ...jection of LN2 Reduce number of nozzles in sensor area Valve may need throttling Reduce pressure of tank Injection too close to sensor Change location of nozzle Ice build up around nozzle causing dire...

Страница 40: ...ce each if necessary Jammed conveyor belt motor hums Press the E stop button check for jam and correct cause Belt drive not activated Activate belt drive Emergency stop is activated Pull to reset the...

Страница 41: ...speed Exhaust fan not running Exhaust system not switched on Activate exhaust system Circuit breaker of motor failed Reset breaker No LN2 injection LN2 injection not activated Start LN2 injection Tank...

Страница 42: ...Shaft Fan 30 570263 Coupling Fan Shaft Split 5 8 I D 30 570354 Bearing Fan Shaft 30 550561 Sleeve Bearing 30 570303 Fan Blade P1171 High Pitch 30 570207 Fan Blade P1179 Low Pitch 11 2 CONTROL CABINET...

Страница 43: ...er Part Description 30 570010 LN2 Injection Solenoid Valve 30 570360 Sensor Temperature RTD type 30 570004 Motor Conveyor Drive 1 3HP 30 550491 Gasket Door Curved Spun Polyester 30 550490 Gasket Door...

Страница 44: ...OPERATION MAINTENANCE MANUAL CompactFreezer 42 12 Appendices Appendix A Liquid Nitrogen MSDS...

Страница 45: ...OPERATION MAINTENANCE MANUAL CompactFreezer 43 Appendix B Reference Drawings...

Страница 46: ...OPERATION MAINTENANCE MANUAL CompactFreezer 44 Appendix C Component Manuals...

Отзывы: