13
SAR:
Once the contamination levels have been confirmed, check to make sure the airline
filter is working correctly. Follow the Radex
®
Airline Filter Instruction Manual.
Make sure the area is ventilated and monitored:
Make sure that the area is well ventilated and that regular air samples are taken to
confirm the atmosphere stays within the levels recommended by governing bodies. For
Supplied Air, it is recommended to use a GX4
®
Gas Monitor. Follow the GX4
®
Gas Monitor
Instruction Manual.
If you have any questions, ask your employer.
DO NOT ENTER THE WORK AREA
if any of the following conditions exist:
Atmosphere is immediately dangerous to life or health.
You cannot escape without the aid of the respirator.
Atmosphere contains less than 21% ±1% oxygen.
Contaminants are in excess of regulations or recommendations.
Contaminants or contaminant concentrations are unknown.
Work area is poorly ventilated.
The work area is a confined space (unless proper measures are taken for confined spaces).
The temperature is outside the range of -10°C to +60°C (14°F to 140°F).
Used with systems including electrical parts, PX4 AIR
®
, VISION-LINK
™
, 16-922 COMMS-
LINK
™
or 09-913 PTT, do not use when a flammable or explosive atmosphere is present.
LEAVE THE WORK AREA IMMEDIATELY IF:
Any product component becomes damaged.
Vision is impaired.
Airflow stops or slows down, or alarm sounds. Do not use Powered Air Purifying Respirators if
airflow is less than 170 lpm (6 cfm).
Breathing becomes difficult.
You become dizzy, nauseous, too hot, too cold, or ill.
Your eyes, nose, or skin become irritated.
The work area is a confined space (unless proper measures are taken for confined spaces).
You taste, smell, or see contaminants inside the helmet.
You have any other reason to suspect that the respirator is not providing adequate protection.
PRODUCT CARE
Never place the helmet on hot surfaces. Do not apply paints, solvents, adhesives or self-
adhesive labels except as instructed by RPB
®
. This product may be adversely affected by certain
chemicals.
See the “Respirator Setup and Care” section for more specific cleaning instructions.
INSTRUCTIONS FOR SPECIFIC USES OR ENVIRONMENTS
Welding
See Operator Setup and Use - Z-LINK+
®
Welding Configuration (page 26) and ADF Operation
Содержание Z-LINK ADF