Calculated Resistance
An operator can perform a secondary Calculated Resistance check. See page 28 for an explanation how
Calculated Resistance works and instructions how to turn the option on.
NOTE:
A secondary Calculated Resistance check can only be performed when fusing in Barcode or Manual Barcode
Modes. It will not work if fusing in Manual Mode.
DO NOT TURN ON CALCULATED RESISTANCE UNLESS A 4-WIRE MEASUREMENT FAILS.
TURNING ON CALCULATED RESISTANCE DOES NOT GUARANTEE THAT A FUSION WILL BE SUCCESSFUL.
BEFORE TURNING ON CALCULATED RESISTANCE, ALWAYS CONFIRM WITH THE FITTING MANUFACTURER
THAT IT IS AN ACCEPTABLE METHOD OF MEASUREMENT FOR THEIR SPECIFIED FITTING.
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
COR
RECT PER THE FITTING MANUFACTURER’S RECOMMENDATIONS FOR FUSING THE ATTACHED FITTING
UNDER THE CURRENT AMBIENT CONDITIONS.
If you press the
START button
to begin a fusion and receive Warning Code 55 (see page 43 for Error & Warning
Code Definitions), the processor will display a screen similar to the following:
WARNING 55 RECEIVED
Resistance 16.578
Min:1.21 Max:1.78
Hold START to clear
Press the
START button
to clear the warning code. The processor will display a screen similar to the following:
4 wire res. is out
of range. Ignore and
do secondary check?
START=Yes STOP=No
At this time, the operator has two options:
1.
Cancel the fusion.
2.
Perform the secondary check and attempt to continue fusing the fitting.
Содержание Jackman Fusion Equipment
Страница 1: ......
Страница 2: ......
Страница 49: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 47 of 48 Page Intentionally Left Blank...
Страница 50: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 48 of 48 Page Intentionally Left Blank...
Страница 51: ......
Страница 52: ...JACKMAN FUSION EQUIPMENT 715 S 59th Ave W Duluth MN 55807 USA www jackmanfusion com 218 302 4770...