JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 46 of 48
specified heat soak time
was observed.
144
The output is cycling and
cannot be controlled to
the requested level.
This is more than likely caused by a fluctuating power supply. Eliminate
all extension cords and make sure that the processor is the only device
operating on the circuit.
145
There is an error
communicating with the
USB Flash Drive.
Make sure the drive is formatted as FAT or FAT32 with a cluster size of
512 bytes.