JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 43 of 48
WARNING & ERROR CODES
Warning Codes
A warning code will be displayed when a situation exists that (in the manufacturer’s opinion) may adversely
affect the performance of the processor over time. Warning codes are designed for informational purposes
only and have no effect on the outcome of a fusion. A warning code could be displayed either before or after
a fusion and will require user acknowledgement before normal operation can resume.
IT IS STRONGLY RECOMMENDED THAT OPERATORS FAMILIARIZE THEMSELVES WITH ALL WARNING CODES
AND THEIR CAUSES AND ADHERE TO THE RECOMMENDATIONS BELOW WHEN THEY ARE RECEIVED.
Code Description
Cause
Recommendation
55
Resistance
out of range
Occurs when the measured
resistance does not match the
resistance identified in the fitting
barcode.
Only applies when Calculated
Resistance setting is turned on.
The operator may choose to continue and
perform a secondary Calculated Resistance
check, or they may cancel the fusion and
resolve the problem. See Error Code 102 for
possible resolutions.
USING CALCULATED RESISTANCE IS NOT
RECOMMENDED UNLESS A 4-WIRE
MEASUREMENT FAILS. SEE PAGE 28 FOR
DETAILS.
Error Codes
Code Problem
Resolution
100
The barcode was scanned
successfully, however the
processor cannot decode
the information into valid
fusion parameters.
This is not a barcode wand error or scanning problem. Verify that the
barcode is an ISO standard 24 digit fitting barcode.
101
Ambient temperature is
out of range.
Verify the temperature displayed in the CONNECT FITTING screen is
reasonable and within the range specified in the Specification Table
(See
page 7)
. If the temperature displayed differs significantly from the actual
temperature, then there is a processor problem and it must be returned
for service.
102
Measured resistance does
not match resistance
identified in the barcode.
Check the Output Lead Ends and fitting adapters for excessive wear
and/or damage. If the Output Lead Ends and fitting adapters are in good
condition, reattach the processor to the fitting and try again. If the
problem persists, there is more than likely a calibration or output cable
malfunction.
103 Shorted Coil in Fitting.
Check for a short stab or a shorted coil.
Содержание Jackman Fusion Equipment
Страница 1: ......
Страница 2: ......
Страница 49: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 47 of 48 Page Intentionally Left Blank...
Страница 50: ...JACKMAN FUSION EQUIP ELECTROFUSION PROCESSOR OPERATORS MANUAL REV 0 Page 48 of 48 Page Intentionally Left Blank...
Страница 51: ......
Страница 52: ...JACKMAN FUSION EQUIPMENT 715 S 59th Ave W Duluth MN 55807 USA www jackmanfusion com 218 302 4770...