When the Alternative unit is activated, the controller will convert the heat
quantity into the quantity of fossil fuels (coal, oil or gas) saved, or the CO
2
emission
saved respectively. The alternative Unit can be selected. A Conversion factor
must be adjusted for the calculation. The conversion factor depends on the ar-
rangement in use and has to be determined individually.
Note:
In 2-store systems, the heat quantity of both stores can be measured with
one fl owmeter.
Heat quantity measurements already activated will appear in the HQM menu above
the menu item new HQM… in numerical order.
If an activated heat quantity measurement is selected, the above mentioned sub-
menu with all adjustment values will re-open.
In order to delete a heat quantity measurement, select Delete function and con-
fi rm the safety enquiry by selecting Yes. The heat quantity measurement deleted
will disappear from the list and become available for selection in the new HQM…
menu again.
With the menu item Function, a heat quantity measurement already selected can
be temporarily deactivated or re-activated respectively. In this case, all adjustments
will remain stored.
HQM / new HQM…
Adjustment
channel
Description
Adjustment range /
selection
Factory setting
Flow sen.
Flow sensor selection
system dependent
system dependent
Return sen.
Return sensor selection
system dependent
system dependent
Flow rate sen.
Flow rate sensor option
Yes, No
No
Flow rate sen.
Flow rate sensor selection Imp.1, Gd1, Gd2
-
Flow r…
Flow rate (only if Flow rate
sen. = No)
1.0 … 500.0 l/min
3.0 l/min
Relay
Relay selection
system dependent
system dependent
Fluid type
Heat transfer fl uid
Tyfocor LS, Propylene gly-
col, Ethylene glycol, Water
Water
Ratio
Glycol ratio in the heat
transfer fl uid (only if Fluid
type = Propylene glycol or
Ethylene glycol)
5 … 100 %
40 %
Alternative unit Alternative unit option
Yes, No
No
Unit
Alternative display unit
Coal, Gas, Oil, CO
2
CO
2
Factor
Conversion factor
0.0000001 … 100.0000000 0.5000000
Funct.
Activation / Deactivation
Activated, Deactivated
Deactivated