Installation manual

5

R2CND0 R2TND012~024A4AA
Wall-mounted condensing boiler
3P469346-4E – 2017.07

Pump  anti-blockage  system

:  The  pump  operates  for  30  seconds

every 24 hours during long periods of inactivity to ensure it does not
get stuck. To enable this function, the unit must be connected to the
power supply.

Three-way valve anti-blockage system

: In cases where the unit is

non-operational  for  prolonged  periods  of  time,  the  three-way  valve
switches its position every 24 hours to prevent it from getting stuck.
To  enable  this  function,  the  unit  must  be  connected  to  the  power
supply.

Safety  against  dry  operation

:  This  is  controlled  by  the  pressure

sensor.  It  turns  off  the  unit  and  ensures  system  safety  when  the
water pressure of the heating installation falls below 0.6 bar for any
reason.

Flame  ionisation  control

:  This  is  controlled  by  the  ionisation

electrode. It checks whether a flame forms on the burner surface or
not.  If  there  is  no  flame,  it  turns  the  unit  off  to  stop  gas  flow  and
warns the user.

High pressure protection

:

Pressure  sensor

:  When  heating  system  pressure  reaches

2.8  bar,  control  unit  stops  heating  operation  thus  preventing  the
pressure from rising.

Safety  valve

:  When  the  water  pressure  of  the  heating  circuit

exceeds  3  bar,  some  water  is  automatically  drained  from  the
safety valve to keep the pressure below 3 bar thus protecting the
boiler and heating installation.

Automatic  air  vents

:  There  are  two  air  vents;  one  on  the  pump,

other on the heat exchanger. They help discharging the air inside the
installation  and  heating  circuit  to  avoid  air  traps  and  consequent
operational problems.

Frost protection safety system

: This function protects the unit and

heating  installation  from  frost  damages.  It  is  controlled  by  the  flow
temperature  sensor,  which  is  located  at  the  outlet  of  the  main  heat
exchanger. This protection activates the boiler pump when the water
temperature drops below 13°C and it activates the burner when the
water temperature drops below 8°C. The unit keeps running until the
temperature reaches 20°C. To enable this function, the unit must be
connected to the power supply and its main gas valve must be open.
Any damage caused by frost is not covered by the warranty.

Low  voltage  safety  system

:  This  is  controlled  by  the  control  unit.

When  the  supply  voltage  drops  below  170  Volt,  the  boiler  goes  to
error  mode.  It  is  a  blocking  error  and  the  boiler  will  operate  without
reset  after  supply  voltage  is  above  180  Volt.  It  is  recommended  to
use a voltage regulator of suitable power and type in locations with
voltage fluctuations below this limit for faultless operation.

High  electric  supply  current  protection  system

:  A  fuse  on  the

control  unit  protects  equipment  and  wiring  against  the  damaging
effects  of  electrical  faults  which  is  caused  by  excess  currents,  and
disables  equipment  which  is  faulty.  The  fuse  "blows"  (opens)  when
the current carried exceeds the rated value for an excessive time.

Automatic  by-pass  system

:  This  ensures  that  the  flow  is  at  all

times  continued,  to  avoid  overheating  of  the  heat  exchanger.  This
system  is  also  supported  with  a  special  by-pass  function  in  the
control unit software.

Combustion control safety system

: Boiler control unit monitors the

flame  to  avoid  bad  combustion  and  risky  conditions.  It  also  makes
self-inspection against its own malfunctioning and to keep emissions
always at a low level.

3.2

Dimensions

Top view

200

DN100

127

200

Front view and right side view

400

613.7

590

255.5

Bottom view of model R2CND024A4AA

53

161.7

105.8

101.4

22.4

65

61

71.9

65.1

Bottom view of models R2TND012A4AA, R2TND018A4AA and
R2TND024A4AA

53 30

96

22.4

108

105.8

45.8

101.4

48.5

105.8

29

Содержание R2TND012A4AA

Страница 1: ...Installation manual Wall mounted condensing boiler English Installation manual Wall mounted condensing boiler R2CND024A4AA R2TND012A4AA R2TND018A4AA R2TND024A4AA...

Страница 2: ...is t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra n...

Страница 3: ...propriately disposed of in accordance with local and national regulations The components are easy to separate and the plastics are marked This allows the various components to be sorted for appropriat...

Страница 4: ...ommissioning repair configuration and service must be performed by qualified competent persons in accordance with local standards and regulations Incorrect installation of this unit may harm the user...

Страница 5: ...es It is controlled by the flow temperature sensor which is located at the outlet of the main heat exchanger This protection activates the boiler pump when the water temperature drops below 13 C and i...

Страница 6: ...rode p High limit thermostat q Fan r Return temperature sensor s Silencer t Automatic air vent pump u Water pressure sensor v By pass w Boiler pump x Domestic hot water flow sensor y Domestic hot wate...

Страница 7: ...max m h 0 12 0 46 0 12 0 69 0 12 0 96 0 12 0 96 Combustion products mass flow rate min max G20 g s 1 32 5 12 1 32 7 78 1 32 10 75 1 32 10 75 Combustion products mass flow rate min max G31 g s 1 23 4 7...

Страница 8: ...ters 50 C return temperature at heater inlet 4 Installation 4 1 To open the unit WARNING Only qualified competent persons are allowed to open the unit Certain actions explained in this document such a...

Страница 9: ...the current I E E Wiring Regulations local Building Regulations or any other local regulations currently in service The intake air must not include chemicals that may cause corrosion toxic gas format...

Страница 10: ...ght and related system charge pressure are given below h p 6 m 0 8 bar 7 m 0 9 bar 8 m 1 0 bar 9 m 1 1 bar 10 m 1 2 bar 11 m 1 3 bar 12 m 1 4 bar 13 m 1 5 bar h h System water height m p System charge...

Страница 11: ...done to avoid discomfort of the user 4 7 Residual pump lift graph The residual pump lift graph shows the amount of pump lift mbar that remains for the central heating circuit 0 0 100 200 300 400 500 6...

Страница 12: ...ge while the gas line to the boiler is open see 5 3 To check for gas leakage on page 24 In case gas piping is adjacent to the wall and is to be connected to the gas pipe connection of the boiler with...

Страница 13: ...ny damage that may occur this way WARNING Use a dedicated power circuit Never use a power supply cable shared by another unit The unit runs on 230 V AC 50 Hz power A power cable is delivered with the...

Страница 14: ...nds that are sent with the unit must be assembled to the bottom sheet of the boiler in case connection of these options Below you can see the cable glands placement PG 9 PG 9 PG 7 PG 7 Holes on the bo...

Страница 15: ...012 024A4AA Wall mounted condensing boiler 3P469346 4E 2017 07 4 8 6 Wiring diagram DANGER RISK OF ELECTROCUTION Disconnect the power supply for more than 10 minutes before servicing Model R2CND024A4A...

Страница 16: ...ace Ext3 X1M Opentherm room thermostat Ext4 X2M External power output 230 V AC Ext5 X2M Reserved not in use X1M X4 X11 X12 Low voltage terminal strip X2M X1 X2 High voltage terminal strip 4 8 7 Guidel...

Страница 17: ...that products of combustion discharging from the terminal cannot re enter the building or other buildings through ventilators windows doors other sources of natural air infiltration or forced ventila...

Страница 18: ...it Optional c 45 elbow 60 100 d Extension 60 100 mm e Flat roof outlet kit f 90 elbow 60 100 g 45 elbow 60 100 h 30 elbow 60 100 i Extension 60 100 L 500 1000 mm Allowable flue length for C33x R2TND R...

Страница 19: ...nd lengths of the flue system For R2TND Nominal combustion products temperature 77 C Combustion products mass flow rate 10 75 g s Overheat combustion products temperature 90 C Minimum combustion produ...

Страница 20: ...use flue outlet duct length must be shortened with the same length Type C83x twin pipes flue system The boiler draws combustion air from outside via a separate supply pipe routed through the external...

Страница 21: ...h 140 19 6 69 2 DN 80 Flex square and rough 130 17 0 60 0 DN 80 Flex square and rough 120 12 2 43 0 DN 80 Star square and rough 140 47 5 167 8 DN 80 Star square and rough 120 33 3 117 9 Allowable flue...

Страница 22: ...e 60 100 with measurement point EKFGP4667 90 elbow 60 100 with measurement point DRMEEA60100BA 90 elbow 60 100 EKFGP4660 90 elbow 80 125 EKFGP4810 45 elbow 60 100 EKFGP4661 45 elbow 80 125 EKFGP4811 3...

Страница 23: ...om the installation with the manual air vent screws on the radiators Make sure screws are tightened after venting 10 If after the venting the pressure decreases below 0 8 bar refill with water until t...

Страница 24: ...Back button INFORMATION Only qualified persons have access to servicing parameters The passwords needed to access service parameters are written in servicing instructions 5 Commissioning WARNING Only...

Страница 25: ...buttons together five seconds Sweeper mode will be deactivated and boiler will return to normal operation mode Sweeper mode also finishes automatically after 15 minutes 5 4 2 To commission the centra...

Страница 26: ......

Страница 27: ......

Страница 28: ...usland Our partners abroad Unsere Partner im Ausland Nos partenaires l tranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granic Na i partne i v zahrani http...

Отзывы: