4 Installation

Installation manual

22

R2CND0 R2TND012~024A4AA

Wall-mounted condensing boiler

3P469346-4E – 2017.07

Equivalent length of options

90° elbow 60 mm

1.5 m

45° elbow 60 mm

1.0 m

90° elbow 80 mm

2.0 m

45° elbow 80 mm

1.0 m

Subtract  equivalent  length  value  of  bends  from  the  allowable  flue
length value.

a

c

d

e

L

b

a

90° elbow 60 mm

b

Extension 60 mm

Optional:

c

90° elbow 60 mm

d

45° elbow 60 mm

e

Extension 60 mm
L= 250-500-1000-1500-2000 mm

Type B33 (open flue system)

The  multi  served  chimnet  is  a  system  that  is  a  part  of  the  building
and has a separate CE marking. The connection between the boiler
and the shaft must be obtained via ROTEX.

b

c

a

d

L

a

B33 flue kit

Optional:

b

90° elbow 60 mm

c

45° elbow 60 mm

d

Extension 60 mm

L = 500 mm

Flue parts order codes

Required  flue  kits  and/or  additional  parts  can  be  ordered  from
ROTEX with the order codes given in the table below:

Flue part

Order code

Wall terminal kit 60/100 (C13x)

DRWTER60100AA

Wall terminal kit 80/125 (C13x)

EKFGW6359

Roof terminal kit 60/100 (C33x)

EKFGP6837

Roof terminal kit 80/125 (C33x)

EKFGP6864

Tee 60/100 with measurement point

EKFGP4667

90° elbow 60/100 with measurement point

DRMEEA60100BA

90° elbow 60/100

EKFGP4660

90° elbow 80/125

EKFGP4810

45° elbow 60/100

EKFGP4661

45° elbow 80/125

EKFGP4811

30° elbow 60/100

EKFGP4664

30° elbow 80/125

EKFGP4814

Extension duct 60/100

500 mm

EKFGP4651

1000 mm

EKFGP4652

Extension duct 80/125

500 mm

EKFGP4801

1000 mm

EKFGP4802

Tile roof outlet kit 60/100

18°/22°

EKFGS0518

23°/27°

EKFGS0519

25°/45°

EKFGP7910

43°/47°

EKFGS0523

48°/52°

EKFGS0524

53°/57

EKFGS0525

Tile roof outlet kit 80/125

18°/22°

EKFGT6300

23°/27°

EKFGT6301

25°/45°

EKFGP7909

43°/47°

EKFGT6305

48°/52°

EKFGT6306

53°/57°

EKFGT6307

Flat roof outlet kit

60/100

EKFGP6940

80/125

EKFGW5333

Wall bracket

DN.100

EKFGP4631

DN.125

EKFGP4481

60/100 to 80/125 adapter

DRDECO80125BA

Tee flex boiler connection set

100 mm

EKFGP6368

130 mm

EKFGP6215

Flex + support elbow

60/100

EKFGP6354

60/130

EKFGS0257

Chimney connection

60/100

EKFGP4678

80/125

EKFGS4828

Roof terminal kit 80 mm

EKFGP6864

90° elbow 80 mm

EKFGW4085

45° elbow 80 mm

EKFGW4086

Extension duct 80 mm

500 mm

EKFGW4001

1000 mm

EKFGW4002

2000 mm

EKFGW4004

60/100 to 80/80 adapter

DRDECOP8080BA

Air intake 80 mm (C53 kit)

EKFGV1102

Air intake 80 mm (C83 kit)

EKFGV1101

Flex kit PP DN.80 (C93 kit)

EKFGP2520

Flex kit PP DN.60/80 (C93 kit)

EKFGP1856

Содержание R2TND012A4AA

Страница 1: ...Installation manual Wall mounted condensing boiler English Installation manual Wall mounted condensing boiler R2CND024A4AA R2TND012A4AA R2TND018A4AA R2TND024A4AA...

Страница 2: ...is t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra n...

Страница 3: ...propriately disposed of in accordance with local and national regulations The components are easy to separate and the plastics are marked This allows the various components to be sorted for appropriat...

Страница 4: ...ommissioning repair configuration and service must be performed by qualified competent persons in accordance with local standards and regulations Incorrect installation of this unit may harm the user...

Страница 5: ...es It is controlled by the flow temperature sensor which is located at the outlet of the main heat exchanger This protection activates the boiler pump when the water temperature drops below 13 C and i...

Страница 6: ...rode p High limit thermostat q Fan r Return temperature sensor s Silencer t Automatic air vent pump u Water pressure sensor v By pass w Boiler pump x Domestic hot water flow sensor y Domestic hot wate...

Страница 7: ...max m h 0 12 0 46 0 12 0 69 0 12 0 96 0 12 0 96 Combustion products mass flow rate min max G20 g s 1 32 5 12 1 32 7 78 1 32 10 75 1 32 10 75 Combustion products mass flow rate min max G31 g s 1 23 4 7...

Страница 8: ...ters 50 C return temperature at heater inlet 4 Installation 4 1 To open the unit WARNING Only qualified competent persons are allowed to open the unit Certain actions explained in this document such a...

Страница 9: ...the current I E E Wiring Regulations local Building Regulations or any other local regulations currently in service The intake air must not include chemicals that may cause corrosion toxic gas format...

Страница 10: ...ght and related system charge pressure are given below h p 6 m 0 8 bar 7 m 0 9 bar 8 m 1 0 bar 9 m 1 1 bar 10 m 1 2 bar 11 m 1 3 bar 12 m 1 4 bar 13 m 1 5 bar h h System water height m p System charge...

Страница 11: ...done to avoid discomfort of the user 4 7 Residual pump lift graph The residual pump lift graph shows the amount of pump lift mbar that remains for the central heating circuit 0 0 100 200 300 400 500 6...

Страница 12: ...ge while the gas line to the boiler is open see 5 3 To check for gas leakage on page 24 In case gas piping is adjacent to the wall and is to be connected to the gas pipe connection of the boiler with...

Страница 13: ...ny damage that may occur this way WARNING Use a dedicated power circuit Never use a power supply cable shared by another unit The unit runs on 230 V AC 50 Hz power A power cable is delivered with the...

Страница 14: ...nds that are sent with the unit must be assembled to the bottom sheet of the boiler in case connection of these options Below you can see the cable glands placement PG 9 PG 9 PG 7 PG 7 Holes on the bo...

Страница 15: ...012 024A4AA Wall mounted condensing boiler 3P469346 4E 2017 07 4 8 6 Wiring diagram DANGER RISK OF ELECTROCUTION Disconnect the power supply for more than 10 minutes before servicing Model R2CND024A4A...

Страница 16: ...ace Ext3 X1M Opentherm room thermostat Ext4 X2M External power output 230 V AC Ext5 X2M Reserved not in use X1M X4 X11 X12 Low voltage terminal strip X2M X1 X2 High voltage terminal strip 4 8 7 Guidel...

Страница 17: ...that products of combustion discharging from the terminal cannot re enter the building or other buildings through ventilators windows doors other sources of natural air infiltration or forced ventila...

Страница 18: ...it Optional c 45 elbow 60 100 d Extension 60 100 mm e Flat roof outlet kit f 90 elbow 60 100 g 45 elbow 60 100 h 30 elbow 60 100 i Extension 60 100 L 500 1000 mm Allowable flue length for C33x R2TND R...

Страница 19: ...nd lengths of the flue system For R2TND Nominal combustion products temperature 77 C Combustion products mass flow rate 10 75 g s Overheat combustion products temperature 90 C Minimum combustion produ...

Страница 20: ...use flue outlet duct length must be shortened with the same length Type C83x twin pipes flue system The boiler draws combustion air from outside via a separate supply pipe routed through the external...

Страница 21: ...h 140 19 6 69 2 DN 80 Flex square and rough 130 17 0 60 0 DN 80 Flex square and rough 120 12 2 43 0 DN 80 Star square and rough 140 47 5 167 8 DN 80 Star square and rough 120 33 3 117 9 Allowable flue...

Страница 22: ...e 60 100 with measurement point EKFGP4667 90 elbow 60 100 with measurement point DRMEEA60100BA 90 elbow 60 100 EKFGP4660 90 elbow 80 125 EKFGP4810 45 elbow 60 100 EKFGP4661 45 elbow 80 125 EKFGP4811 3...

Страница 23: ...om the installation with the manual air vent screws on the radiators Make sure screws are tightened after venting 10 If after the venting the pressure decreases below 0 8 bar refill with water until t...

Страница 24: ...Back button INFORMATION Only qualified persons have access to servicing parameters The passwords needed to access service parameters are written in servicing instructions 5 Commissioning WARNING Only...

Страница 25: ...buttons together five seconds Sweeper mode will be deactivated and boiler will return to normal operation mode Sweeper mode also finishes automatically after 15 minutes 5 4 2 To commission the centra...

Страница 26: ......

Страница 27: ......

Страница 28: ...usland Our partners abroad Unsere Partner im Ausland Nos partenaires l tranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granic Na i partne i v zahrani http...

Отзывы: